The inhibit or enable constituent allows the user to electronically plough on or off the output voltage of a ability provide without having to interrupt the input air-conditioning or DC voltage amongst a relay or switch. This is useful during initial railroad train of the system, during maintenance or for saving unloose energy during periods of not operation.
An tardily agency of remembering the deviation betwixt the 2 types is that “Inhibit” requires that the user has to produce an activity to plough off the output voltage, where equally “Enable”, the user has to produce an activity to plough on the output voltage.
It is criterion amongst most DC-DC converters for example, to utilize an enable type constituent that requires the remote on / off pivot to hold upwards connected to the negative input (primary side) to activate the output voltage. This is oftentimes referred to equally “negative logic”. First fourth dimension users of DC-DC converters oftentimes forget to push clit that pivot depression in addition to telephone telephone Tech Support to complain most a not functioning ability supply.
AC-DC ability supplies normally convey a remote on / off referenced to the secondary side for security reasons. An “Inhibit” type function, requiring an external voltage, is normally to a greater extent than pop on uncomplicated ability supplies because in i lawsuit the output voltage is turned off, whatsoever auxiliary voltages driving the secondary command circuit is too turned off.
One agency ability provide designers overcome this is to convey an integrated independent “stand-by” auxiliary output similar the i used on pc ability supplies. This is too used to ability the secondary command circuit in addition to permit a unopen contact to the 0V final to enable the output.
If the organisation uses several ability supplies, the remote on /off tin dismiss hold upwards used to sequence the voltages. I know of thermal printer applications where if the 5V provide driving the command circuit goes faulty, they postulate the 24V motor drive hold upwards inhibited to avoid embarrassing amounts of newspaper shooting out!
Where several dissimilar voltages are used to drive processors, sequencing the output voltages is oftentimes critical to avoid damaging those devices. The 3.3V output is rarely allowed to hold upwards applied earlier the 5V is present.
The manufacture criterion I2C based PMBus is forthwith gaining popularity. Power supplies such equally TDK-Lambda’s HFE serial tin dismiss hold upwards remotely turned on or off using the PMBus software, either equally a grouping or individually for charge shedding to relieve energy.
Showing posts with label Signals. Show all posts
Showing posts with label Signals. Show all posts
Monday, 17 December 2018
Info!! How Does The Ac Neglect Indicate Function Inward A Ability Supply?
I was lately talking to ane of our Design Engineers most my weblog together with he suggested a clarification of the functioning of the air conditioning Fail signal would locomote a adept topic. He stated that he was oftentimes asked “at what input voltage does the air conditioning Fail signal operate?”
Influenza A virus subtype H5N1 ability supply’s air conditioning Fail signal is used to provide a alert to the user that the air conditioning input ability has either been lost, or is dropping inwards voltage to a quest that the ability render volition shortly no longer locomote able to regulate or provide power.
Customers using such a signal volition together with then convey a brusque catamenia of fourth dimension (typically five to 10ms) inwards which to shop whatever information or starting fourth dimension an orderly shutdown of their system.
Internal to the ability supply, the air conditioning Fail circuit is unremarkably a unproblematic circuit comparison a reference alongside the voltage of a primary side housekeeping supply. In the outcome that voltage drops, get is removed from an opto-coupler together with the user provided alongside an air conditioning Fail signal soil change.
Before the widespread work of Power Factor Correction (PFC), the air conditioning Fail did indeed operate at a ready input voltage. I recollect equally a Test Technician reducing the input voltage alongside a variable transformer (variac) to banking concern gibe the function.
On those non PFC ability supplies, the air conditioning input is peak rectified equally shown below. The principal switching converter operates off that unregulated high voltage buss, the value of which is a straight business office of the air conditioning input voltage – betwixt 120 together with 375VDC.
On ability supplies alongside PFC though, that high voltage osculate is regulated using a boost circuit – to approximately 360VDC. Now whatever alter to the air conditioning input voltage (within the normal operating range) is non reflected inwards a alter inwards the DC buss; thence a unlike exam method must locomote used.
Use a storage oscilloscope to monitor the output voltage, the air conditioning Fail signal together with if desired, an isolation transformer to display the air conditioning input voltage.
Turn off the input voltage together with mensurate the fourth dimension betwixt the air conditioning Fail signal going depression together with the output voltage starting to drop. This is the total of alert fourth dimension yous volition have.
Unlike alongside a non PFC ability supply, this alert fourth dimension volition non locomote related to input voltage.
Influenza A virus subtype H5N1 ability supply’s air conditioning Fail signal is used to provide a alert to the user that the air conditioning input ability has either been lost, or is dropping inwards voltage to a quest that the ability render volition shortly no longer locomote able to regulate or provide power.
Customers using such a signal volition together with then convey a brusque catamenia of fourth dimension (typically five to 10ms) inwards which to shop whatever information or starting fourth dimension an orderly shutdown of their system.
Internal to the ability supply, the air conditioning Fail circuit is unremarkably a unproblematic circuit comparison a reference alongside the voltage of a primary side housekeeping supply. In the outcome that voltage drops, get is removed from an opto-coupler together with the user provided alongside an air conditioning Fail signal soil change.
Before the widespread work of Power Factor Correction (PFC), the air conditioning Fail did indeed operate at a ready input voltage. I recollect equally a Test Technician reducing the input voltage alongside a variable transformer (variac) to banking concern gibe the function.
On those non PFC ability supplies, the air conditioning input is peak rectified equally shown below. The principal switching converter operates off that unregulated high voltage buss, the value of which is a straight business office of the air conditioning input voltage – betwixt 120 together with 375VDC.
![]() |
| Click to enlarge |
On ability supplies alongside PFC though, that high voltage osculate is regulated using a boost circuit – to approximately 360VDC. Now whatever alter to the air conditioning input voltage (within the normal operating range) is non reflected inwards a alter inwards the DC buss; thence a unlike exam method must locomote used.
Use a storage oscilloscope to monitor the output voltage, the air conditioning Fail signal together with if desired, an isolation transformer to display the air conditioning input voltage.
Turn off the input voltage together with mensurate the fourth dimension betwixt the air conditioning Fail signal going depression together with the output voltage starting to drop. This is the total of alert fourth dimension yous volition have.
Unlike alongside a non PFC ability supply, this alert fourth dimension volition non locomote related to input voltage.
Sunday, 16 December 2018
Info!! How Tin Laissez Passer On The Axe Ane Purpose My Ability Supply’S Alert Signals?
Many ability provide alert signals, such every bit air conditioning Fail, DC Good, etc., utilize optocouplers or optical isolators every bit a agency of transferring alert signals from the ability provide to the end-users equipment without straight connections. The primary role of an optocoupler is to preclude noise, dry reason loops, and/or high voltages from the ability provide from damaging the end-equipment to which the signals connect. Below is a typical schematic diagram of an optocoupler that consists of an LED on the input side together with a phototransistor on the output side. Signals from ability provide activate the LED, which inward plough activates the electrically isolated phototransistor.
Typical ability provide alert signals may include air conditioning Fail, DC Good, Over-Temp, together with Inverter OK.
Pull-Up Resistors - When using open-collector alert signals an external pull-up resistor is required. This pull-up resistor needs to live on selected together with connected betwixt the alert output (collector) together with an external voltage rootage (+VCC). The role of the resistor is to trammel the sum of electrical current that flows through the open-collector transistor. For example, inward to a greater extent than or less applications the electrical current should non orbit 10mA, however, ever banking concern tally your ability provide manual to confirm the maximum allowable electrical current together with maximum +VCC voltage.
External +VCC – The +VCC voltage that is connected to the pull-up resistor(s) for the alert signal(s) should come upwards from an external voltage rootage if maximum isolation is desired. However, inward to a greater extent than or less cases ability supplies come upwards amongst an Auxiliary DC Output, which is ever introduce every bit long every bit the air conditioning input voltage is present. In to a greater extent than or less applications, this Auxiliary DC Output tin sack live on used every bit the +VCC for the alert signals except for “AC Fail.”
Logic Ground – If an isolated logic dry reason is present, it ordinarily needs to live on tied to either the (-) Vout of the ability provide or to the dry reason of the end-equipment system.
Alarm Signal Levels - In around cases, when an alert status is Not introduce the open-collector transistor output(s) volition live on On (or logic Low). If an alert status should occur, the open-collector output(s) volition plough Off (or logic High). But, dissimilar supplies tin sack accept dissimilar alert logic levels, together with therefore you lot should ever banking concern tally your ability supply’s education manual to decide the supply’s alert logic levels, amongst together with without alert conditions.
Combining Alarm Signals – The diagram below shows an illustration of how “DC-OK” signals from iii dissimilar ability supplies that are mounted inward a ability organisation rack tin sack live on combined (OR’d) to cast a unmarried signal In this example, the +VCC comes from the Aux DC Output of the ability organisation is connected to iii divide pull-up resistors. These pull-up resistors (10K ohm) connect to an open-collector “DC-OK” output from each of the iii ability supplies. And, all open-collector transistors accept a mutual dry reason connexion (similar to Fig H5N1 above).
Normally, if all supplies are OK, their DC-OK signals volition live on inward the depression acre (approx. +0.6Vdc or lower). Should 1 of the ability supply’s output’s fail, its “DC-OK” open-collector transistor volition plough off together with that output volition become high via the pull-up resistor to the +12 to +15Vdc aux provide output. This positive “high” signal volition frontward bias the diode together with crusade the combined “DC-OK” alert output to become high (relative to the Return or Ground line), which indicates that 1 of the iii supplies accept failed “DC Not OK”. The indicator calorie-free on the failed provide volition demo which provide has failed.
Alternatively, each of the “DC-OK” signals from the private supplies inward this ability organisation could accept been connected separately to a monitoring organisation (without combining them). The payoff of doing this is that the specific failed provide could live on identified remotely without viewing the front end panel mounted indicators.
Review Hot Swap/Rack Mount Front End ability supplies from TDK-Lambda
Typical ability provide alert signals may include air conditioning Fail, DC Good, Over-Temp, together with Inverter OK.
Fig A: These opto-isolated, open-collector alert signals portion a mutual ground
Fig. B: This opto-isolated alert signal has a divide output together with ground
Pull-Up Resistors - When using open-collector alert signals an external pull-up resistor is required. This pull-up resistor needs to live on selected together with connected betwixt the alert output (collector) together with an external voltage rootage (+VCC). The role of the resistor is to trammel the sum of electrical current that flows through the open-collector transistor. For example, inward to a greater extent than or less applications the electrical current should non orbit 10mA, however, ever banking concern tally your ability provide manual to confirm the maximum allowable electrical current together with maximum +VCC voltage.
Logic Ground – If an isolated logic dry reason is present, it ordinarily needs to live on tied to either the (-) Vout of the ability provide or to the dry reason of the end-equipment system.
Alarm Signal Levels - In around cases, when an alert status is Not introduce the open-collector transistor output(s) volition live on On (or logic Low). If an alert status should occur, the open-collector output(s) volition plough Off (or logic High). But, dissimilar supplies tin sack accept dissimilar alert logic levels, together with therefore you lot should ever banking concern tally your ability supply’s education manual to decide the supply’s alert logic levels, amongst together with without alert conditions.
Combining Alarm Signals – The diagram below shows an illustration of how “DC-OK” signals from iii dissimilar ability supplies that are mounted inward a ability organisation rack tin sack live on combined (OR’d) to cast a unmarried signal In this example, the +VCC comes from the Aux DC Output of the ability organisation is connected to iii divide pull-up resistors. These pull-up resistors (10K ohm) connect to an open-collector “DC-OK” output from each of the iii ability supplies. And, all open-collector transistors accept a mutual dry reason connexion (similar to Fig H5N1 above).
Normally, if all supplies are OK, their DC-OK signals volition live on inward the depression acre (approx. +0.6Vdc or lower). Should 1 of the ability supply’s output’s fail, its “DC-OK” open-collector transistor volition plough off together with that output volition become high via the pull-up resistor to the +12 to +15Vdc aux provide output. This positive “high” signal volition frontward bias the diode together with crusade the combined “DC-OK” alert output to become high (relative to the Return or Ground line), which indicates that 1 of the iii supplies accept failed “DC Not OK”. The indicator calorie-free on the failed provide volition demo which provide has failed.
Review Hot Swap/Rack Mount Front End ability supplies from TDK-Lambda
Friday, 14 December 2018
Info!! Using The Inhibit Or Enable Business Office On Ability Supplies
The inhibit or enable constituent allows the user to electronically plough on or off the output voltage of a ability provide without having to interrupt the input air-conditioning or DC voltage amongst a relay or switch. This is useful during initial railroad train of the system, during maintenance or for saving unloose energy during periods of not operation.
An tardily agency of remembering the deviation betwixt the 2 types is that “Inhibit” requires that the user has to produce an activity to plough off the output voltage, where equally “Enable”, the user has to produce an activity to plough on the output voltage.
It is criterion amongst most DC-DC converters for example, to utilize an enable type constituent that requires the remote on / off pivot to hold upwards connected to the negative input (primary side) to activate the output voltage. This is oftentimes referred to equally “negative logic”. First fourth dimension users of DC-DC converters oftentimes forget to push clit that pivot depression in addition to telephone telephone Tech Support to complain most a not functioning ability supply.
AC-DC ability supplies normally convey a remote on / off referenced to the secondary side for security reasons. An “Inhibit” type function, requiring an external voltage, is normally to a greater extent than pop on uncomplicated ability supplies because in i lawsuit the output voltage is turned off, whatsoever auxiliary voltages driving the secondary command circuit is too turned off.
One agency ability provide designers overcome this is to convey an integrated independent “stand-by” auxiliary output similar the i used on pc ability supplies. This is too used to ability the secondary command circuit in addition to permit a unopen contact to the 0V final to enable the output.
If the organisation uses several ability supplies, the remote on /off tin dismiss hold upwards used to sequence the voltages. I know of thermal printer applications where if the 5V provide driving the command circuit goes faulty, they postulate the 24V motor drive hold upwards inhibited to avoid embarrassing amounts of newspaper shooting out!
Where several dissimilar voltages are used to drive processors, sequencing the output voltages is oftentimes critical to avoid damaging those devices. The 3.3V output is rarely allowed to hold upwards applied earlier the 5V is present.
The manufacture criterion I2C based PMBus is forthwith gaining popularity. Power supplies such equally TDK-Lambda’s HFE serial tin dismiss hold upwards remotely turned on or off using the PMBus software, either equally a grouping or individually for charge shedding to relieve energy.
An tardily agency of remembering the deviation betwixt the 2 types is that “Inhibit” requires that the user has to produce an activity to plough off the output voltage, where equally “Enable”, the user has to produce an activity to plough on the output voltage.
It is criterion amongst most DC-DC converters for example, to utilize an enable type constituent that requires the remote on / off pivot to hold upwards connected to the negative input (primary side) to activate the output voltage. This is oftentimes referred to equally “negative logic”. First fourth dimension users of DC-DC converters oftentimes forget to push clit that pivot depression in addition to telephone telephone Tech Support to complain most a not functioning ability supply.
AC-DC ability supplies normally convey a remote on / off referenced to the secondary side for security reasons. An “Inhibit” type function, requiring an external voltage, is normally to a greater extent than pop on uncomplicated ability supplies because in i lawsuit the output voltage is turned off, whatsoever auxiliary voltages driving the secondary command circuit is too turned off.
One agency ability provide designers overcome this is to convey an integrated independent “stand-by” auxiliary output similar the i used on pc ability supplies. This is too used to ability the secondary command circuit in addition to permit a unopen contact to the 0V final to enable the output.
If the organisation uses several ability supplies, the remote on /off tin dismiss hold upwards used to sequence the voltages. I know of thermal printer applications where if the 5V provide driving the command circuit goes faulty, they postulate the 24V motor drive hold upwards inhibited to avoid embarrassing amounts of newspaper shooting out!
Where several dissimilar voltages are used to drive processors, sequencing the output voltages is oftentimes critical to avoid damaging those devices. The 3.3V output is rarely allowed to hold upwards applied earlier the 5V is present.
The manufacture criterion I2C based PMBus is forthwith gaining popularity. Power supplies such equally TDK-Lambda’s HFE serial tin dismiss hold upwards remotely turned on or off using the PMBus software, either equally a grouping or individually for charge shedding to relieve energy.
Info!! How Does The Ac Neglect Indicate Function Inward A Ability Supply?
I was lately talking to ane of our Design Engineers most my weblog together with he suggested a clarification of the functioning of the air conditioning Fail signal would locomote a adept topic. He stated that he was oftentimes asked “at what input voltage does the air conditioning Fail signal operate?”
Influenza A virus subtype H5N1 ability supply’s air conditioning Fail signal is used to provide a alert to the user that the air conditioning input ability has either been lost, or is dropping inwards voltage to a quest that the ability render volition shortly no longer locomote able to regulate or provide power.
Customers using such a signal volition together with then convey a brusque catamenia of fourth dimension (typically five to 10ms) inwards which to shop whatever information or starting fourth dimension an orderly shutdown of their system.
Internal to the ability supply, the air conditioning Fail circuit is unremarkably a unproblematic circuit comparison a reference alongside the voltage of a primary side housekeeping supply. In the outcome that voltage drops, get is removed from an opto-coupler together with the user provided alongside an air conditioning Fail signal soil change.
Before the widespread work of Power Factor Correction (PFC), the air conditioning Fail did indeed operate at a ready input voltage. I recollect equally a Test Technician reducing the input voltage alongside a variable transformer (variac) to banking concern gibe the function.
On those non PFC ability supplies, the air conditioning input is peak rectified equally shown below. The principal switching converter operates off that unregulated high voltage buss, the value of which is a straight business office of the air conditioning input voltage – betwixt 120 together with 375VDC.
On ability supplies alongside PFC though, that high voltage osculate is regulated using a boost circuit – to approximately 360VDC. Now whatever alter to the air conditioning input voltage (within the normal operating range) is non reflected inwards a alter inwards the DC buss; thence a unlike exam method must locomote used.
Use a storage oscilloscope to monitor the output voltage, the air conditioning Fail signal together with if desired, an isolation transformer to display the air conditioning input voltage.
Turn off the input voltage together with mensurate the fourth dimension betwixt the air conditioning Fail signal going depression together with the output voltage starting to drop. This is the total of alert fourth dimension yous volition have.
Unlike alongside a non PFC ability supply, this alert fourth dimension volition non locomote related to input voltage.
Influenza A virus subtype H5N1 ability supply’s air conditioning Fail signal is used to provide a alert to the user that the air conditioning input ability has either been lost, or is dropping inwards voltage to a quest that the ability render volition shortly no longer locomote able to regulate or provide power.
Customers using such a signal volition together with then convey a brusque catamenia of fourth dimension (typically five to 10ms) inwards which to shop whatever information or starting fourth dimension an orderly shutdown of their system.
Internal to the ability supply, the air conditioning Fail circuit is unremarkably a unproblematic circuit comparison a reference alongside the voltage of a primary side housekeeping supply. In the outcome that voltage drops, get is removed from an opto-coupler together with the user provided alongside an air conditioning Fail signal soil change.
Before the widespread work of Power Factor Correction (PFC), the air conditioning Fail did indeed operate at a ready input voltage. I recollect equally a Test Technician reducing the input voltage alongside a variable transformer (variac) to banking concern gibe the function.
On those non PFC ability supplies, the air conditioning input is peak rectified equally shown below. The principal switching converter operates off that unregulated high voltage buss, the value of which is a straight business office of the air conditioning input voltage – betwixt 120 together with 375VDC.
![]() |
| Click to enlarge |
On ability supplies alongside PFC though, that high voltage osculate is regulated using a boost circuit – to approximately 360VDC. Now whatever alter to the air conditioning input voltage (within the normal operating range) is non reflected inwards a alter inwards the DC buss; thence a unlike exam method must locomote used.
Use a storage oscilloscope to monitor the output voltage, the air conditioning Fail signal together with if desired, an isolation transformer to display the air conditioning input voltage.
Turn off the input voltage together with mensurate the fourth dimension betwixt the air conditioning Fail signal going depression together with the output voltage starting to drop. This is the total of alert fourth dimension yous volition have.
Unlike alongside a non PFC ability supply, this alert fourth dimension volition non locomote related to input voltage.
Thursday, 13 December 2018
Info!! How Tin Laissez Passer On The Axe Ane Purpose My Ability Supply’S Alert Signals?
Many ability provide alert signals, such every bit air conditioning Fail, DC Good, etc., utilize optocouplers or optical isolators every bit a agency of transferring alert signals from the ability provide to the end-users equipment without straight connections. The primary role of an optocoupler is to preclude noise, dry reason loops, and/or high voltages from the ability provide from damaging the end-equipment to which the signals connect. Below is a typical schematic diagram of an optocoupler that consists of an LED on the input side together with a phototransistor on the output side. Signals from ability provide activate the LED, which inward plough activates the electrically isolated phototransistor.
Typical ability provide alert signals may include air conditioning Fail, DC Good, Over-Temp, together with Inverter OK.
Pull-Up Resistors - When using open-collector alert signals an external pull-up resistor is required. This pull-up resistor needs to live on selected together with connected betwixt the alert output (collector) together with an external voltage rootage (+VCC). The role of the resistor is to trammel the sum of electrical current that flows through the open-collector transistor. For example, inward to a greater extent than or less applications the electrical current should non orbit 10mA, however, ever banking concern tally your ability provide manual to confirm the maximum allowable electrical current together with maximum +VCC voltage.
External +VCC – The +VCC voltage that is connected to the pull-up resistor(s) for the alert signal(s) should come upwards from an external voltage rootage if maximum isolation is desired. However, inward to a greater extent than or less cases ability supplies come upwards amongst an Auxiliary DC Output, which is ever introduce every bit long every bit the air conditioning input voltage is present. In to a greater extent than or less applications, this Auxiliary DC Output tin sack live on used every bit the +VCC for the alert signals except for “AC Fail.”
Logic Ground – If an isolated logic dry reason is present, it ordinarily needs to live on tied to either the (-) Vout of the ability provide or to the dry reason of the end-equipment system.
Alarm Signal Levels - In around cases, when an alert status is Not introduce the open-collector transistor output(s) volition live on On (or logic Low). If an alert status should occur, the open-collector output(s) volition plough Off (or logic High). But, dissimilar supplies tin sack accept dissimilar alert logic levels, together with therefore you lot should ever banking concern tally your ability supply’s education manual to decide the supply’s alert logic levels, amongst together with without alert conditions.
Combining Alarm Signals – The diagram below shows an illustration of how “DC-OK” signals from iii dissimilar ability supplies that are mounted inward a ability organisation rack tin sack live on combined (OR’d) to cast a unmarried signal In this example, the +VCC comes from the Aux DC Output of the ability organisation is connected to iii divide pull-up resistors. These pull-up resistors (10K ohm) connect to an open-collector “DC-OK” output from each of the iii ability supplies. And, all open-collector transistors accept a mutual dry reason connexion (similar to Fig H5N1 above).
Normally, if all supplies are OK, their DC-OK signals volition live on inward the depression acre (approx. +0.6Vdc or lower). Should 1 of the ability supply’s output’s fail, its “DC-OK” open-collector transistor volition plough off together with that output volition become high via the pull-up resistor to the +12 to +15Vdc aux provide output. This positive “high” signal volition frontward bias the diode together with crusade the combined “DC-OK” alert output to become high (relative to the Return or Ground line), which indicates that 1 of the iii supplies accept failed “DC Not OK”. The indicator calorie-free on the failed provide volition demo which provide has failed.
Alternatively, each of the “DC-OK” signals from the private supplies inward this ability organisation could accept been connected separately to a monitoring organisation (without combining them). The payoff of doing this is that the specific failed provide could live on identified remotely without viewing the front end panel mounted indicators.
Review Hot Swap/Rack Mount Front End ability supplies from TDK-Lambda
Typical ability provide alert signals may include air conditioning Fail, DC Good, Over-Temp, together with Inverter OK.
Fig A: These opto-isolated, open-collector alert signals portion a mutual ground
Fig. B: This opto-isolated alert signal has a divide output together with ground
Pull-Up Resistors - When using open-collector alert signals an external pull-up resistor is required. This pull-up resistor needs to live on selected together with connected betwixt the alert output (collector) together with an external voltage rootage (+VCC). The role of the resistor is to trammel the sum of electrical current that flows through the open-collector transistor. For example, inward to a greater extent than or less applications the electrical current should non orbit 10mA, however, ever banking concern tally your ability provide manual to confirm the maximum allowable electrical current together with maximum +VCC voltage.
Logic Ground – If an isolated logic dry reason is present, it ordinarily needs to live on tied to either the (-) Vout of the ability provide or to the dry reason of the end-equipment system.
Alarm Signal Levels - In around cases, when an alert status is Not introduce the open-collector transistor output(s) volition live on On (or logic Low). If an alert status should occur, the open-collector output(s) volition plough Off (or logic High). But, dissimilar supplies tin sack accept dissimilar alert logic levels, together with therefore you lot should ever banking concern tally your ability supply’s education manual to decide the supply’s alert logic levels, amongst together with without alert conditions.
Combining Alarm Signals – The diagram below shows an illustration of how “DC-OK” signals from iii dissimilar ability supplies that are mounted inward a ability organisation rack tin sack live on combined (OR’d) to cast a unmarried signal In this example, the +VCC comes from the Aux DC Output of the ability organisation is connected to iii divide pull-up resistors. These pull-up resistors (10K ohm) connect to an open-collector “DC-OK” output from each of the iii ability supplies. And, all open-collector transistors accept a mutual dry reason connexion (similar to Fig H5N1 above).
Normally, if all supplies are OK, their DC-OK signals volition live on inward the depression acre (approx. +0.6Vdc or lower). Should 1 of the ability supply’s output’s fail, its “DC-OK” open-collector transistor volition plough off together with that output volition become high via the pull-up resistor to the +12 to +15Vdc aux provide output. This positive “high” signal volition frontward bias the diode together with crusade the combined “DC-OK” alert output to become high (relative to the Return or Ground line), which indicates that 1 of the iii supplies accept failed “DC Not OK”. The indicator calorie-free on the failed provide volition demo which provide has failed.
Review Hot Swap/Rack Mount Front End ability supplies from TDK-Lambda
Info!! Ability Render Ascent As Well As Autumn Output Characteristics
A mutual interrogation asked past times our customers is “what are the ability supply’s ascent together with autumn output characteristics?” Our commons answer “it depends” sometimes raises an eyebrow. Let’s induce got a expect at why.
As you lot know, at that spot are 2 ways a ability furnish tin displace hold upward turned-on together with off. One method is to apply or take the air conditioning input ability via a switch or circuit breaker to the supply. Another method is purpose the Remote On/Off command of the supply, if the unit of measurement has this feature. Let’s examine both methods.
The curves below (Fig. 1) demo the typical delay betwixt when the air conditioning input ability (Vin) is applied together with the ability supply’s output reaches its rated voltage of 12V nether total charge conditions. As tin displace hold upward seen (in this example) amongst a depression air conditioning input of 85VAC the output turn-on delay is slightly to a greater extent than than amongst higher input voltages. However, inwards this example, the typical turn-on delay is nearly 250ms together with the output ascent fourth dimension is nearly 25ms.

Conditions:
The side past times side curves (Fig. 2) demo the same ability supply’s output (with 100% load) when the air conditioning input is removed. The fourth dimension delay from when the air conditioning ability is removed (or lost) is referred to equally the Hold-Up fourth dimension spec. For this supply, the specified minimum hold-up fourth dimension is 16ms. As shown below, the measured hold-up fourth dimension is nearly 30ms, which meets the spec. The output autumn fourth dimension is about 10ms, when measured from 90% to 10%. Note that the set out energy is pulled from the ability furnish rattling apace due to the heavy charge on its output.
By comparison, without a charge (zero load), the curves below (Fig. 3) demo that the Hold-Up fourth dimension of the ability furnish increases substantially to nearly 1.8 seconds, together with the output drops to null inwards nearly half dozen seconds!
Below is a graph (Fig. 4) for this ability furnish that shows how minimum Hold-Up fourth dimension varies equally the charge changes betwixt 10% together with 100% (maximum load).
Next, nosotros shall review how the remote on/off command (if used) tin displace deport upon the ability supply’s output rise/fall, together with delay times.
Conditions:
In the higher upward curves (Fig. 5), the remote On/Off command is the bottom line together with higher upward that is the ability supply’s DC OK dot level. This province of affairs assumes the air conditioning input inwards ever on. As tin displace hold upward seen, from the fourth dimension the Remote On is activated (goes from high to depression logic level); it takes the output nearly 150ms to accomplish its total rated voltage. And, the DC OK dot changes nation when the output marking is nearly 75% of its rated voltage, which inwards this representative is nearly 125ms afterwards the Remote On dot is activated.
The side past times side laid upward of curves (Fig. 6) demo the contrary situation, where the Remote On/Off dot is used to plough the ability furnish off.
There is nearly 25ms delay afterwards the Remote On/Off changes nation to when the Vout reduces to about 75% its nominal. In addition, at that fourth dimension the DC OK dot changes state. The output autumn time, from 90% to 10% of nominal, is about 15ms.
From the higher upward curves together with explanations, I believe the reader tin displace reckon why our answer at the kickoff was "it depends." In these types of measurements, delay times are inwards many cases to a greater extent than of import than ascent together with autumn times. Other considerations include the air conditioning input voltage, the load, operating temperatures, measuring criteria together with the pattern specifications for the ability supply.
As you lot know, at that spot are 2 ways a ability furnish tin displace hold upward turned-on together with off. One method is to apply or take the air conditioning input ability via a switch or circuit breaker to the supply. Another method is purpose the Remote On/Off command of the supply, if the unit of measurement has this feature. Let’s examine both methods.
The curves below (Fig. 1) demo the typical delay betwixt when the air conditioning input ability (Vin) is applied together with the ability supply’s output reaches its rated voltage of 12V nether total charge conditions. As tin displace hold upward seen (in this example) amongst a depression air conditioning input of 85VAC the output turn-on delay is slightly to a greater extent than than amongst higher input voltages. However, inwards this example, the typical turn-on delay is nearly 250ms together with the output ascent fourth dimension is nearly 25ms.
Conditions:
| Vin | : 85VAC (A) |
| : 115VAC (B) | |
| : 230VAC (C) | |
| : 264VAC (D) | |
| lout | : 100% |
| Ta | : 25°C |
Fig. 1
The side past times side curves (Fig. 2) demo the same ability supply’s output (with 100% load) when the air conditioning input is removed. The fourth dimension delay from when the air conditioning ability is removed (or lost) is referred to equally the Hold-Up fourth dimension spec. For this supply, the specified minimum hold-up fourth dimension is 16ms. As shown below, the measured hold-up fourth dimension is nearly 30ms, which meets the spec. The output autumn fourth dimension is about 10ms, when measured from 90% to 10%. Note that the set out energy is pulled from the ability furnish rattling apace due to the heavy charge on its output.
Fig. 2
By comparison, without a charge (zero load), the curves below (Fig. 3) demo that the Hold-Up fourth dimension of the ability furnish increases substantially to nearly 1.8 seconds, together with the output drops to null inwards nearly half dozen seconds!
Fig. 3
Below is a graph (Fig. 4) for this ability furnish that shows how minimum Hold-Up fourth dimension varies equally the charge changes betwixt 10% together with 100% (maximum load).
Fig. 4
Next, nosotros shall review how the remote on/off command (if used) tin displace deport upon the ability supply’s output rise/fall, together with delay times.
Conditions:
| Vin | : 115VAC (A) |
| lout | : 100% |
| Ta | : 25°C |
Fig. v
In the higher upward curves (Fig. 5), the remote On/Off command is the bottom line together with higher upward that is the ability supply’s DC OK dot level. This province of affairs assumes the air conditioning input inwards ever on. As tin displace hold upward seen, from the fourth dimension the Remote On is activated (goes from high to depression logic level); it takes the output nearly 150ms to accomplish its total rated voltage. And, the DC OK dot changes nation when the output marking is nearly 75% of its rated voltage, which inwards this representative is nearly 125ms afterwards the Remote On dot is activated.
The side past times side laid upward of curves (Fig. 6) demo the contrary situation, where the Remote On/Off dot is used to plough the ability furnish off.
Fig. 6
There is nearly 25ms delay afterwards the Remote On/Off changes nation to when the Vout reduces to about 75% its nominal. In addition, at that fourth dimension the DC OK dot changes state. The output autumn time, from 90% to 10% of nominal, is about 15ms.
From the higher upward curves together with explanations, I believe the reader tin displace reckon why our answer at the kickoff was "it depends." In these types of measurements, delay times are inwards many cases to a greater extent than of import than ascent together with autumn times. Other considerations include the air conditioning input voltage, the load, operating temperatures, measuring criteria together with the pattern specifications for the ability supply.