Info!! What’S All This Materials Nigh Digital Power?

It seems that every 2-3 weeks an article or intelligence statement almost “Digital Power” appears inwards electronic pattern periodicals or online intelligence links. In fact, i manufacture newsletter seems to survive having a dear thing with digital power, every bit it mentions it inwards simply almost every issue.

So what is all this fuss almost Digital Power in addition to what is it anyway? Well, the uncomplicated respond is that at that topographic point are 2 basic types of digital power. These are Digital Control (used internal to the mightiness devices) in addition to Digital Power Management (provides external command in addition to communications betwixt mightiness devices in addition to a principal controller).

Digital Control
The bulk of switchmode AC-DC in addition to DC-DC mightiness supplies/converters exercise analog techniques to regulate/control the output voltage, current, in addition to mightiness ingredient correction circuits, etc. The closest that most of these devices come upward to looking a chip digital (On/Off states) inwards nature is past times employing Pulse Width Modulation (PWM) inwards their switching regulator circuits; but fifty-fifty that is a chip of a stretch.

In recent years, novel integrated circuits (ICs) convey been developed that tin supplant “analog” command ICs in addition to discrete circuits, which are used extensively inwards all mightiness devices, with those that are, at to the lowest degree inwards part, “digital” inwards nature. These internal ICs in addition to circuits perform such command functions as: voltage rule (VR), mightiness ingredient correction (PFC), pulse width modulation (PWM) control, internal monitoring/alarms, in addition to external communications.

The payoff of these digital ICs is that they tin survive programmed past times engineers with digital or analog electronics training. And, since the Universities are pumping out to a greater extent than digital (e.g., calculator science) than analog engineers these days, these digital ICs are becoming attractive. However, at introduce the cost of these digital ICs (along with NRE for the equipment needed to programme the devices) is all the same higher than for the mature analog ICs. Nonetheless, around predict that these IC costs volition locomote equal inside the adjacent 12 months or so. Influenza A virus subtype H5N1 potential disadvantage of these digital ICs is that, past times their nature, they require a high speed clock to operate, which tin add together to the radiated in addition to conducted dissonance coming from the mightiness provide or converter. However, advanced functions such every bit error diagnostics/prevention in addition to improved mightiness efficiencies are with the promises of the novel digital command ICs.


Digital Power Management
As mentioned above, Digital Power Management (DPM) involves the external command in addition to communications betwixt mightiness supplies (or converters) in addition to a principal controller. Currently, many analog-based mightiness solutions already convey the mightiness to communicate with an external calculator or controller via digital communications links (e.g., RS232, RS485, GPIB, or I2C bus).

Newer DPM command in addition to communications formats convey evolved that are designed to operate with the novel digitally-controlled mightiness devices. These include DPM technologies such every bit PMBus (Power Management Bus) in addition to Z-One. Sadly, these technologies are non compatible or interchangeable. In fact, currently at that topographic point are lawsuits betwixt the backers of both of these technologies.

If I were a potential user of these Digital Power Management schemes, I would remain clear of them until the lawsuits are settled (expected to spill out inside the adjacent 12 months), rather than detect out after that the cost of these DPM ICs or controllers convey substantially increased due to royalties that must straight off survive paid to the society that won the lawsuit.

The potential advantages of the DPM in addition to digital mightiness technologies inwards general, include enhanced bidirectional communications, error diagnostics, remote programming of the linked mightiness supplies/converters, automatic compensation of dynamic input in addition to output charge changes, in addition to overall improvements inwards efficiencies that relate to green-power.

In Summary
Although “Digital Power” is a pop buzzword these days, peculiarly past times those companies who convey developed or adopted the technologies, the bottom business volition ever be: “What produce I instruct for my money?” At present, at that topographic point are hardly whatsoever mightiness provide or converter applications that “must have” digital mightiness when compared to the many lower cost in addition to field-proven analog solutions that exist.

For example, during their novel power-product pattern in addition to evolution process, Lambda has designed in-parallel devices that employed both analog along with those that exercise digital command ICs in addition to technologies. In all cases, the finally conclusion on which engineering ultimately goes into production has been based on comparative price/performance factors; which is the dominant conclusion ingredient for their customers.

When the fourth dimension comes that digital mightiness products offering the same or improve functioning in addition to reliability, along with the ”needed features”, at the same or lower toll every bit analog-based products, that is when Digital Power volition locomote the winning technology. Realistically, someday digital mightiness volition provide a price/performance payoff over purely analog mightiness devices. Who knows for sure when that fourth dimension volition come.

Info!! What Is The Deviation Betwixt Flake Charge Per Unit Of Measurement As Well As Baud Charge Per Unit Of Measurement Inward Ability Provide Remote Communications?

Many modern ability supplies, such every bit TDK-Lambda's novel Z+ programmable supplies in addition to the HFE series of rack mountain supplies, directly characteristic series information interfaces such every bit I2C, USB 2.0, in addition to RS485, to elevate a few. The transmission rates of these series information interfaces are specified every bit bits-per-second (bits/s) and/or baud rate. As a refresher, hither is a brief review of the divergence betwixt Bit rates in addition to Baud rates.

The Bit charge per unit of measurement is the lay out of bits (binary zeros in addition to ones) that are transmitted during 1 minute (bits/s). The Baud charge per unit of measurement refers to the lay out of dot units (symbols or characters) that are transmitted per second.

Equation for Baud Rate:
baud charge per unit of measurement = fleck charge per unit of measurement (bits/s) ÷ N, where northward is the lay out of bits represented past times each dot shift (symbol or character).
For example, if the fleck charge per unit of measurement is 9,600 bits/s in addition to the communications format demand eight bits per symbol, the baud charge per unit of measurement would last 9,600 bits/s divided past times eight bits, which would equal 1200 baud.

Equation for Bit Rate:
Bits/s = baud per minute ten the lay out of bits per symbol
Therefore, from the higher upward example:
Bits/s = 1200 baud ten eight bits = 9,600 bits/s


Sunday, 16 December 2018

Info!! Encoders Vs. Potentiometers: Which 1 Is Best For Programmable Ability Supplies?

Recently I asked the production managing director of TDK-Lambda’s novel Z+ Series of programmable ability supplies a question, “Why operate rotary encoders to adapt the output voltage as well as electrical flow confine inward preference to potentiometers?”


“The response is relatively simple,” he said; it’s all most digital circuitry compatibility as well as resolution”. The commutation payoff to using a rotary encoder over a potentiometer is that that the digital signal produced past times the encoder eliminates the demand for the analog to digital (A/D) conversion that is required when potentiometers are used. In addition, multi-turn encoders tin provide to a greater extent than accurate as well as higher resolution set-points than potentiometers.

Let’s position this into context: if a unmarried plough potentiometer were to live on used to adapt the output voltage on a 20V rated model, ane total plough would typically correspond 20V; this resolution is relatively depression as well as thence non precise plenty for a programmable ability supply. Of course, multi-turn potentiometers could live on employed but these are bulkier than as well as non every bit reliable every bit encoders are.

Digital rotary encoders are available amongst rattling high resolutions as well as tin operate inward dual modes, including a coarse as well as fine mode. In the coarse mode, the encoder operates amongst a lower resolution; for example, a 20V rated model would require most 6 turns of the encoder knob to adapt the output from zero to xx volts. In the fine mode, ane plough equates to an to a greater extent than or less twoscore millivolts, thereby providing a much higher resolution as well as to a greater extent than precise set-point.

To avoid an inadvertent alter to the voltage setting during use, a front end panel locking characteristic is needed. With an encoder, this locking business office is done via software as well as internal memory, whereas a potentiometer requires a less reliable mechanical locking mechanism.

The Z+ programmable ability render employs 2 encoders every bit set-point controls for the output voltage as well as current. The encoder’s digital output feeds the unit’s memory, which retains the terminal set-points prior to the air-conditioning ability beingness turned off as well as on, either intentionally or due to an unplanned ability outage, as well as keeps the output disabled until the user enables it (aka “safe-start” mode). In the “auto-restart” mode, the Z+ ability render remembers its terminal output set-points as well as when the ability is turned dorsum on, it resumes its normal operation, which is handy for unattended applications.

To encounter to a greater extent than details including videos most the encoder driven Z+ programmable ability supplies, delight operate this link: http://www.us.tdk-lambda.com/lp/products/zplus-series.htm

Saturday, 15 December 2018

Info!! The Advantages Of Using A Ability Provide Incorporating Digital Command To Ability Non-Linear Loads


I was of late tasked amongst doing a presentation on the advantages of ability supplies incorporating Digital Control to ability non-linear loads, thus I thought I would portion the content amongst you.

A non-linear charge is i that does non acquit similar an ideal resistor, inward that the electrical flow drawn from the ability provide is non proportional to voltage and/or the initial currents are frequently much higher than the rating of the ability supply.

These loads tin crusade problems for ability supplies, but are genuinely acquaint inward many applications:

Large switched capacitor banks

Point of Load DC-DC converters

Thermal printers

DC motors

The master copy number from a ability supply’s indicate of persuasion is that the charge tin activate the internal over-current protection.  Over-current protection (OCP) is an essential characteristic for a ability supply, but the ability provide is commonly expected to recover automatically amongst no manual intervention.

So to get-go with, let’s facial expression at the types of OCP. There are several basic methods used:

Constant Current

Fold Back

Fold Forward

Hiccup

Constant Current

When an overload status occurs, the output voltage falls but the output electrical flow remains at a fixed level.  This type of protection is non good suited for delivering peak loads equally it tin Pb to the ability provide latching.

 
Fold back

When the electrical flow drawn reaches the OCP limit, the voltage falls, but this fourth dimension the electrical flow decreases equally the overload gets heavier.  Again this type of protection is non good suited for delivering peak loads equally it tin consequence inward the ability provide latching.
 
 
Fold forward

When the electrical flow drawn reaches the OCP limit, the voltage falls.  This fourth dimension the output electrical flow increases to a laid maximum at curt circuit.

Fold frontwards is good suited for powering upward motors, but requires heavier arrangement charge cabling to handgrip the additional overload current.

 
Hiccup

At the OCP limit, the ability provide turns off for a curt interval together with and thus automatically tries to restart.  Hiccup agency reduces the demand for heavy cabling or pcb traces, together with this type of protection tin move modified to deliver a peak load. 

With traditional Analog Control though, the OCP points together with recovery timing are fixed.

With Digital Control nosotros tin operate software settings to adjust the limits together with timing; for illustration nosotros tin set:

10s for an initial overload condition

60ms for heavy overloads

5ms for a curt circuit status amongst recovery times or 1 to two seconds

Let’s accept an application illustration of a discharged capacitor depository fiscal establishment beingness switched onto an operating ability provide amongst Analog control.

The lower (blue) line is the ability provide current; restarting twice amongst the ability provide electrical flow boundary laid at but about 60A.

The hand (gold) line shows the output eventually recovering, but tolerances amongst the hiccup agency timing could stimulate got prevented a total recovery. 



This fourth dimension the same discharged capacitor depository fiscal establishment is switched into a TDK-Lambda CFE400M provide incorporating digital control.

The bluish line is the current, gilded line is the output voltage

Using Digital Control, nosotros tin laid the thresholds together with timing accurately.

50A for 1.5ms (The curt circuit condition)

30A for 50ms (The over electrical flow condition)
 



Notice that at that spot are no multiple attempts to recover later on the capacitor depository fiscal establishment is applied to the ability supply.

To summarize:

Digital command tin allow for precise together with repeatable electrical flow limiting using charge dependant timing.  We are non restricted to the value of a timing capacitor which tin alter due to:

a) Batch tolerances

b) Aging of the capacitor

c) Capacitor values changing amongst temperature

Digital command allows for slow tailoring for dissimilar applications amongst no physical modification of the ability provide is needed.  All changes are handled amongst software programming!

Power Guy

 

Friday, 14 December 2018

Info!! What’S All This Materials Nigh Digital Power?

It seems that every 2-3 weeks an article or intelligence statement almost “Digital Power” appears inwards electronic pattern periodicals or online intelligence links. In fact, i manufacture newsletter seems to survive having a dear thing with digital power, every bit it mentions it inwards simply almost every issue.

So what is all this fuss almost Digital Power in addition to what is it anyway? Well, the uncomplicated respond is that at that topographic point are 2 basic types of digital power. These are Digital Control (used internal to the mightiness devices) in addition to Digital Power Management (provides external command in addition to communications betwixt mightiness devices in addition to a principal controller).

Digital Control
The bulk of switchmode AC-DC in addition to DC-DC mightiness supplies/converters exercise analog techniques to regulate/control the output voltage, current, in addition to mightiness ingredient correction circuits, etc. The closest that most of these devices come upward to looking a chip digital (On/Off states) inwards nature is past times employing Pulse Width Modulation (PWM) inwards their switching regulator circuits; but fifty-fifty that is a chip of a stretch.

In recent years, novel integrated circuits (ICs) convey been developed that tin supplant “analog” command ICs in addition to discrete circuits, which are used extensively inwards all mightiness devices, with those that are, at to the lowest degree inwards part, “digital” inwards nature. These internal ICs in addition to circuits perform such command functions as: voltage rule (VR), mightiness ingredient correction (PFC), pulse width modulation (PWM) control, internal monitoring/alarms, in addition to external communications.

The payoff of these digital ICs is that they tin survive programmed past times engineers with digital or analog electronics training. And, since the Universities are pumping out to a greater extent than digital (e.g., calculator science) than analog engineers these days, these digital ICs are becoming attractive. However, at introduce the cost of these digital ICs (along with NRE for the equipment needed to programme the devices) is all the same higher than for the mature analog ICs. Nonetheless, around predict that these IC costs volition locomote equal inside the adjacent 12 months or so. Influenza A virus subtype H5N1 potential disadvantage of these digital ICs is that, past times their nature, they require a high speed clock to operate, which tin add together to the radiated in addition to conducted dissonance coming from the mightiness provide or converter. However, advanced functions such every bit error diagnostics/prevention in addition to improved mightiness efficiencies are with the promises of the novel digital command ICs.


Digital Power Management
As mentioned above, Digital Power Management (DPM) involves the external command in addition to communications betwixt mightiness supplies (or converters) in addition to a principal controller. Currently, many analog-based mightiness solutions already convey the mightiness to communicate with an external calculator or controller via digital communications links (e.g., RS232, RS485, GPIB, or I2C bus).

Newer DPM command in addition to communications formats convey evolved that are designed to operate with the novel digitally-controlled mightiness devices. These include DPM technologies such every bit PMBus (Power Management Bus) in addition to Z-One. Sadly, these technologies are non compatible or interchangeable. In fact, currently at that topographic point are lawsuits betwixt the backers of both of these technologies.

If I were a potential user of these Digital Power Management schemes, I would remain clear of them until the lawsuits are settled (expected to spill out inside the adjacent 12 months), rather than detect out after that the cost of these DPM ICs or controllers convey substantially increased due to royalties that must straight off survive paid to the society that won the lawsuit.

The potential advantages of the DPM in addition to digital mightiness technologies inwards general, include enhanced bidirectional communications, error diagnostics, remote programming of the linked mightiness supplies/converters, automatic compensation of dynamic input in addition to output charge changes, in addition to overall improvements inwards efficiencies that relate to green-power.

In Summary
Although “Digital Power” is a pop buzzword these days, peculiarly past times those companies who convey developed or adopted the technologies, the bottom business volition ever be: “What produce I instruct for my money?” At present, at that topographic point are hardly whatsoever mightiness provide or converter applications that “must have” digital mightiness when compared to the many lower cost in addition to field-proven analog solutions that exist.

For example, during their novel power-product pattern in addition to evolution process, Lambda has designed in-parallel devices that employed both analog along with those that exercise digital command ICs in addition to technologies. In all cases, the finally conclusion on which engineering ultimately goes into production has been based on comparative price/performance factors; which is the dominant conclusion ingredient for their customers.

When the fourth dimension comes that digital mightiness products offering the same or improve functioning in addition to reliability, along with the ”needed features”, at the same or lower toll every bit analog-based products, that is when Digital Power volition locomote the winning technology. Realistically, someday digital mightiness volition provide a price/performance payoff over purely analog mightiness devices. Who knows for sure when that fourth dimension volition come.

Thursday, 13 December 2018

Info!! What Is The Deviation Betwixt Flake Charge Per Unit Of Measurement As Well As Baud Charge Per Unit Of Measurement Inward Ability Provide Remote Communications?

Many modern ability supplies, such every bit TDK-Lambda's novel Z+ programmable supplies in addition to the HFE series of rack mountain supplies, directly characteristic series information interfaces such every bit I2C, USB 2.0, in addition to RS485, to elevate a few. The transmission rates of these series information interfaces are specified every bit bits-per-second (bits/s) and/or baud rate. As a refresher, hither is a brief review of the divergence betwixt Bit rates in addition to Baud rates.

The Bit charge per unit of measurement is the lay out of bits (binary zeros in addition to ones) that are transmitted during 1 minute (bits/s). The Baud charge per unit of measurement refers to the lay out of dot units (symbols or characters) that are transmitted per second.

Equation for Baud Rate:
baud charge per unit of measurement = fleck charge per unit of measurement (bits/s) ÷ N, where northward is the lay out of bits represented past times each dot shift (symbol or character).
For example, if the fleck charge per unit of measurement is 9,600 bits/s in addition to the communications format demand eight bits per symbol, the baud charge per unit of measurement would last 9,600 bits/s divided past times eight bits, which would equal 1200 baud.

Equation for Bit Rate:
Bits/s = baud per minute ten the lay out of bits per symbol
Therefore, from the higher upward example:
Bits/s = 1200 baud ten eight bits = 9,600 bits/s


Info!! Encoders Vs. Potentiometers: Which 1 Is Best For Programmable Ability Supplies?

Recently I asked the production managing director of TDK-Lambda’s novel Z+ Series of programmable ability supplies a question, “Why operate rotary encoders to adapt the output voltage as well as electrical flow confine inward preference to potentiometers?”


“The response is relatively simple,” he said; it’s all most digital circuitry compatibility as well as resolution”. The commutation payoff to using a rotary encoder over a potentiometer is that that the digital signal produced past times the encoder eliminates the demand for the analog to digital (A/D) conversion that is required when potentiometers are used. In addition, multi-turn encoders tin provide to a greater extent than accurate as well as higher resolution set-points than potentiometers.

Let’s position this into context: if a unmarried plough potentiometer were to live on used to adapt the output voltage on a 20V rated model, ane total plough would typically correspond 20V; this resolution is relatively depression as well as thence non precise plenty for a programmable ability supply. Of course, multi-turn potentiometers could live on employed but these are bulkier than as well as non every bit reliable every bit encoders are.

Digital rotary encoders are available amongst rattling high resolutions as well as tin operate inward dual modes, including a coarse as well as fine mode. In the coarse mode, the encoder operates amongst a lower resolution; for example, a 20V rated model would require most 6 turns of the encoder knob to adapt the output from zero to xx volts. In the fine mode, ane plough equates to an to a greater extent than or less twoscore millivolts, thereby providing a much higher resolution as well as to a greater extent than precise set-point.

To avoid an inadvertent alter to the voltage setting during use, a front end panel locking characteristic is needed. With an encoder, this locking business office is done via software as well as internal memory, whereas a potentiometer requires a less reliable mechanical locking mechanism.

The Z+ programmable ability render employs 2 encoders every bit set-point controls for the output voltage as well as current. The encoder’s digital output feeds the unit’s memory, which retains the terminal set-points prior to the air-conditioning ability beingness turned off as well as on, either intentionally or due to an unplanned ability outage, as well as keeps the output disabled until the user enables it (aka “safe-start” mode). In the “auto-restart” mode, the Z+ ability render remembers its terminal output set-points as well as when the ability is turned dorsum on, it resumes its normal operation, which is handy for unattended applications.

To encounter to a greater extent than details including videos most the encoder driven Z+ programmable ability supplies, delight operate this link: http://www.us.tdk-lambda.com/lp/products/zplus-series.htm

Info!! The Advantages Of Using A Ability Provide Incorporating Digital Command To Ability Non-Linear Loads


I was of late tasked amongst doing a presentation on the advantages of ability supplies incorporating Digital Control to ability non-linear loads, thus I thought I would portion the content amongst you.

A non-linear charge is i that does non acquit similar an ideal resistor, inward that the electrical flow drawn from the ability provide is non proportional to voltage and/or the initial currents are frequently much higher than the rating of the ability supply.

These loads tin crusade problems for ability supplies, but are genuinely acquaint inward many applications:

Large switched capacitor banks

Point of Load DC-DC converters

Thermal printers

DC motors

The master copy number from a ability supply’s indicate of persuasion is that the charge tin activate the internal over-current protection.  Over-current protection (OCP) is an essential characteristic for a ability supply, but the ability provide is commonly expected to recover automatically amongst no manual intervention.

So to get-go with, let’s facial expression at the types of OCP. There are several basic methods used:

Constant Current

Fold Back

Fold Forward

Hiccup

Constant Current

When an overload status occurs, the output voltage falls but the output electrical flow remains at a fixed level.  This type of protection is non good suited for delivering peak loads equally it tin Pb to the ability provide latching.

 
Fold back

When the electrical flow drawn reaches the OCP limit, the voltage falls, but this fourth dimension the electrical flow decreases equally the overload gets heavier.  Again this type of protection is non good suited for delivering peak loads equally it tin consequence inward the ability provide latching.
 
 
Fold forward

When the electrical flow drawn reaches the OCP limit, the voltage falls.  This fourth dimension the output electrical flow increases to a laid maximum at curt circuit.

Fold frontwards is good suited for powering upward motors, but requires heavier arrangement charge cabling to handgrip the additional overload current.

 
Hiccup

At the OCP limit, the ability provide turns off for a curt interval together with and thus automatically tries to restart.  Hiccup agency reduces the demand for heavy cabling or pcb traces, together with this type of protection tin move modified to deliver a peak load. 

With traditional Analog Control though, the OCP points together with recovery timing are fixed.

With Digital Control nosotros tin operate software settings to adjust the limits together with timing; for illustration nosotros tin set:

10s for an initial overload condition

60ms for heavy overloads

5ms for a curt circuit status amongst recovery times or 1 to two seconds

Let’s accept an application illustration of a discharged capacitor depository fiscal establishment beingness switched onto an operating ability provide amongst Analog control.

The lower (blue) line is the ability provide current; restarting twice amongst the ability provide electrical flow boundary laid at but about 60A.

The hand (gold) line shows the output eventually recovering, but tolerances amongst the hiccup agency timing could stimulate got prevented a total recovery. 



This fourth dimension the same discharged capacitor depository fiscal establishment is switched into a TDK-Lambda CFE400M provide incorporating digital control.

The bluish line is the current, gilded line is the output voltage

Using Digital Control, nosotros tin laid the thresholds together with timing accurately.

50A for 1.5ms (The curt circuit condition)

30A for 50ms (The over electrical flow condition)
 



Notice that at that spot are no multiple attempts to recover later on the capacitor depository fiscal establishment is applied to the ability supply.

To summarize:

Digital command tin allow for precise together with repeatable electrical flow limiting using charge dependant timing.  We are non restricted to the value of a timing capacitor which tin alter due to:

a) Batch tolerances

b) Aging of the capacitor

c) Capacitor values changing amongst temperature

Digital command allows for slow tailoring for dissimilar applications amongst no physical modification of the ability provide is needed.  All changes are handled amongst software programming!

Power Guy