Info!! Mutual Security Standards Used Amongst Ability Supplies

A topic that comes upwards real regularly is what create the diverse security standards pertain to. Here is a brief listing of unremarkably used standards, the equipment that uses them, typical products too their purpose.

Base Standard Country (ies) Equipment Type Generic Product Types Purpose
CCC China Many Many Safety & Quality Mark
CE EU Voluntary annunciation based on miscellaneous standards Many Indicate conformity to standards
CSA 60950 CSA Information Technology Office machines, information & telecom networks, IT, Kiosks Protect against fire, electrical shock, injury
CSA60065 CSA Audio, Video too Similar Video, audio, projectors Protect against fire, electrical shock, injury
CSA60601 CSA Medical Electrical Surgical, monitoring, infirmary equipment Safety
CSA61010-1 CSA Measurement, Control too Laboratory Meters, Oscilloscopes Protect against fire, electrical shock, injury
EN50178 EU Power Power generation, ability installations Safety
EN55011 EU Industrial, scientific, too medical r-f Monitoring equipment, automation controls, measuring Limits too measuring of radio disturbance
EN55015 EU Lighting Lighting, LED lighting, street lighting Limits too measuring of radio disturbance
EN55022 EU Information Technology Office machines, information & telecom networks, IT, Kiosks Emission Limits (radiated too conducted)
EN60065 EU Audio, Video too Similar Video, audio, projectors Protect against fire, electrical shock, injury
EN60601 EU Medical Electrical Surgical, monitoring, infirmary equipment Safety
EN60950-1 EU Information Technology Office machines, information & telecom networks, IT, Kiosks Protect against fire, electrical shock, injury
EN61010-1 EU Measurement, Control too Laboratory Meters, Oscilloscopes Protect against fire, electrical shock, injury
Factory Mutual US Use inwards hazardous locations Oil refinery, petrochemical Protect against explosion
FCC Part 15 US Many Many Emission Limits (radiated too conducted)
ISA 12-12 US Use inwards hazardous locations Oil refinery, petrochemical Protect against explosion
REACH EU Many Many Registration, Evaluation, Authorization too restriction of Chemicals
SEMIF47 US Semiconductor fabrication Die manufacturing, wafer fabs Withstand dips inwards air-conditioning input
UL 60950 UL Information Technology Office machines, information & telecom networks, IT, Kiosks Protect against fire, electrical shock, injury
UL1310 UL Power Supplies DIN Rail, LED lighting, access controls, edifice automation Protect against fire
UL508 UL Industrial Control Process control, manufacturing flora automation Safety
UL60065 UL Audio, Video too Similar Video, audio, projectors Protect against fire, electrical shock, injury
UL60601 UL Medical Electrical Surgical, monitoring, infirmary equipment Safety
UL61010-1 UL Measurement, Control too Laboratory Meters, Oscilloscopes Protect against fire, electrical shock, injury
VCCI Japan Information Technology Office machines, information & telecom networks, IT, Kiosks Limits too measuring of RF emissions
VDE0805 Germany Information Technology Office machines, information & telecom networks, IT, Kiosks Protect against fire, electrical shock, injury

Let me know if this tabular array is helpful.

Info!! How Does The Novel Ul Order Touching On Me?

UL of late announced their offset Transcontinental Mark which denotes production compliance alongside European EN security standards equally good equally the CSA/UL/US Mark for the North American markets.  Basically, UL volition survive providing an “international security certification”.  And, this may impact European security houses similar TUV too others.  Here is what the novel international UL grade it looks like:

Although, at offset glance, this grade looks similar a “UL Listed” ability furnish certification alongside its encircled UL grade (as used for External Power Supplies), UL-EU confirmed that it too applies to stand-alone ingredient ability supplies similar those installed inward all electronic equipment.  Prior to this novel mark, the measure “component ability supply” UL grade for the USA too Canada looked similar this:

Some ability furnish manufacturers convey been reviewing purpose of UL to display the existing C-UL-US grade along alongside the self-declared CE mark.  The CE grade would survive backed upwards alongside an IEC60950-1 CB study equally documented proof of compliance.

It volition survive interesting to encounter how the European exam houses (e.g., TUV) react too if CSA responds alongside their ain version of this novel UL mark.

Info!! Course Of Written Report Two Or Course Of Written Report Ii Ability Supplies?

One enquiry I am oftentimes asked is: “The client is looking for a Class 2 ability supply; what tin y'all offering him?”

My reply is ever “Class 2” or “Class II (with Roman numerals)”, or both?  The interruption on the terminate of the band signifies an explanation is inwards order.

Class 2 is a classification referring to the NEC – National Electric Code.  To avoid potential cable overheating due to excessive currents in addition to electrical shock, the output of the ability render is express to 60VDC or 100VA, (100W when used amongst an AC-DC ability supply).  You volition often run across 24V output DIN track ability supplies or LED drivers rated at 91W rather than 100W because if the ability render is overloaded, whatever tolerance inwards the over electrical flow protection has to live on accounted for.

Often these products volition live on certified to UL1310 in addition to volition listing this inwards the datasheet.  An event of this is TDK-Lambda’s DSP series.  You tin run across from the model selector listing on page 2 of the DSP datasheet that output currents of 4.2A or greater are non approved to UL1310.

Class II (with Roman numerals) refers to ability supplies amongst either a double or reinforced insulation barrier betwixt the input in addition to the output. Class II supplies create non rely on an globe connexion to protect against stupor hazard. Many prison theatre mobile telephone band chargers in addition to laptop ability supplies are Class II.  TDK-Lambda’s DSP serial too are Class II, having simply a Line in addition to Neutral air-conditioning input without a dry reason connection.

H5N1 Class II ability render rating label volition exhibit this symbol:


One wages of Class II is amend surge protection betwixt input in addition to dry reason in addition to commonly a lower globe leakage current.

For to a greater extent than information virtually leakage current, delight run across unopen to other article virtually power render leakage electrical flow testing.

Sunday, 16 December 2018

Info!! What Is A Express Ability Source?

There are many technical details regarding Limited Power Sources (often referred to every bit an LPS) covered inwards the IEC60950-1 security standard, involving a diversity of applications, but I volition encompass but the basic aspects regarding AC-DC ability supplies inwards this weblog article.


Several security standards advert to IEC60950-1 for a broad hit of applications, too 1 of those referrals involves the role of Limited Power Sources.

What is, too why are Limited Power Sources important? Simply put, if a slice of electrical or electronic equipment supplying DC ability to external devices is to move installed yesteryear a tertiary party, such every bit an electrician, the peril of wiring fires & electrical stupor needs to move minimized. That electrician volition non move expected to know all the potential error scenarios too role the appropriate cable thicknesses too insulation to encompass those hazards. By using a Limited Power Source, the organisation wiring tin too move reduced, saving cost.

If a Limited Power Source is used, too thence the electrician’s chore is simplified, fifty-fifty if in that place is a (single) error within of the ability supply.

Some examples of testing that the ability provide manufacturer volition do, to induce upwards one's take away heed the maximum output electrical flow too ability encounter the “Limited Power Source” requirements are:
  1. Check the ability provide at maximum rated load
  2. Increase the charge of the ability provide until it is on the verge of overload
  3. Simulate an internal error yesteryear shorting the current-limiting resistor
  4. Short out the opto-coupler that provides feedback to the command loop
The weather for a “Limited Power Source” AC-DC ability provide are:

1. For a ability provide rated at 30V or less, the next must move met fifty-fifty amongst a unmarried error condition:
    a. The output electrical flow must non top 8A
    b. The output ability must non top 100W
2. For a ability provide rated to a higher house 30V, but non exceeding 60V:
    a. The output electrical flow must non top 150 ÷ Vout
    b. The output ability must non top 100W

This graph shows the limits for Limited Power Sources:




Taking some examples from TDK-Lambda’s DSP series of depression profile DIN track ability supplies:


 
The DSP60-5 is rated at 5V 7A – That would encounter (1b), but when lay into overload it would sure enough non encounter the (1a) boundary of 8A. This model is non listed every bit existence a Limited Power Source.

The DSP60-12 is rated at 12V 4.5A – Overload electrical flow would move unopen to 7A which meets (1a) too the maximum ability is 84W (12V x 7A) which too meets (1b). This model is listed every bit existence a Limited Power Source.

The DSP100-24 is rated at 24V 4.2A – Right out of gate this unit of measurement exceeds 100W, too thence it is non listed every bit a Limited Power Source.

The DSP100-24/C2 is rated at 24V 3.8A – This model truly has a exceptional electrical flow boundary & over ability circuit which strictly limits the output electrical flow too ability nether a error condition, thence it meets the <8A requirement of (b) too the boundary of <100W. Interestingly though, a unmarried error on the command circuit made the output ascent to 30.8V too thence it straight off falls nether the 30-60V boundary of 150 ÷ Vout = 4.8A maximum electrical flow (2b), which it passed. Therefore, this model is listed every bit a Limited Power Source.
 
Test results performed yesteryear the security bodies, such every bit UL, CSA or TUV, are usually constitute inwards the CB written report for the ability supply.
 

Info!! How Does Height Touching On Ac-Dc Ability Supplies?

Most AC-DC ability supplies that run into the security standards per UL/EN 60950-1 for ITE (Information Technology Equipment) applications are designed to run at typical percentage together with manufacturing flora altitudes, which tin vary from slightly inward a higher house ocean grade to equally high equally 2,000 meters (6,562 feet). And, many ability provide manufacturers provide units that are designed together with rated for performance at higher altitudes, upwards to 3,000 meters (9,843 feet) together with hence their supplies tin last used inward major cities located at higher elevations (e.g., Denver, Santa Fe, United Mexican U.S. of A. City, Bogota). Many broadcasting/communications stations/towers are located at altitudes upwards to 3,000 meters or higher inward lodge to maximize their range.

Altitude affects the blueprint of ability supplies since ‘air’ is used equally an electrical insulating medium (aka, dielectric) inward the structure of ability supplies, too equally nearly electronic devices. The density together with dielectric strength (insulating property) of air is real proficient at ocean level, merely at higher altitudes, the thinner air loses around of its dielectric strength, which needs to last compensated for. Switchmode ability supplies run off of high voltages (inputs of xc to 265Vac) together with internally generate fifty-fifty higher voltages (400Vdc or more), which withdraw to last insulated together with contained to forbid high voltage arcing or breakdown inside the supply, together with to protect the end-equipment together with operating personnel.

The drawing below shows a cross department of a typical printed circuit board (PCB), which is comprised of copper electrical conduction paths that our chemically etched on an insulated (dielectric) fiber board stuff (e.g., FR4, woven fiberglass fabric alongside epoxy resin), plus electronic components that are non shown inward this drawing. As tin last seen, the fiber board together with air, combined alongside the distances betwixt the etched conductive traces are the main insulation mediums for the circuit board.

Drawing Credits: Mammano B, ‘Safety Considerations inward Power Supply Design, Underwriters Laboratory / TI
  • The term ‘Clearance’ refers to shortage path betwixt the 2 conductive parts (circuit traces, components, etc.), measured through air.
  • The term ‘Creepage’ refers to the shortage path betwixt 2 conductive parts measured along the surface of the insulation (PCB, insulating materials/barriers, etc.).

What does this conduct maintain to create alongside altitude? Since ‘air’ gets thinner (reduced barometric pressure) at higher altitudes together with becomes less of an insulator, the PCB together with element layouts conduct maintain to last designed alongside sufficient security spacing distances to forbid high voltage arcs or breakdowns betwixt conductors and/or electronic components.

For example, typical ability provide blueprint exercise may permit 8 mm spacing distance betwixt main together with secondary circuits together with iv mm spacing distance betwixt main together with ground. These spacing distances volition vary depending upon the voltage levels betwixt conductors together with components together with the expected humidity, temperatures, pollution levels, together with attitudes.

For those ability products that must last approved per the Chinese CCC organization (required to export supplies into China), the novel Chinese Safety Standard GB 4943.1-2011, which is like to UL/EN 60950, requires strict specs for creepage together with clearance distances. As of Dec 1, 2012, the primary-to-secondary clearances must increment yesteryear a factor of 1.48 to qualify the provide for performance upwards to 5,000 meters, since many regions inward China are located at high altitudes. The option for CCC certified ability supplies is that they must clearly marked alongside a alert label that states that the ability provide must last used below 2,000 meters (see tabular array below).

The base of operations blueprint height for ITE ability supplies is 2,000 meters. However, equally mentioned before, equally the height increases, the air becomes a poorer insulator together with the spacing distances conduct maintain to last increased per the next tabular array (assuming an 8 mm clearance at 2000m).

Altitude (meters)Barometric Pressure (kPa)Multiplication Factor for ClearanceResulting Clearance (mm)
200080.01.008.00
300070.01,149.12
400062.01.2910.32
500054.01.4811.84

As tin last seen from this table, if a ability provide is to last operated at 5,000 meters, its conductor/components clearances must last increased yesteryear 48% compared to a provide designed for 2,000 meters.

The other major number of high altitudes on ability supplies is that the less dense air does non deport estrus equally well. To compensate for higher altitudes, ability supplies withdraw to last derated, or employ larger estrus sinks, or conduct maintain increased forced air flow, or a combination of these to insure proper cooling. In addition, the ability provide must last designed alongside the proper conductor together with element clearances equally discussed above.

In summary, whenever an application requires that a ability provide must run at altitudes inward a higher house 2,000 meters (6,562 feet), e'er cheque alongside the manufacturer to create upwards one's hear if this is acceptable, or if an alternate model that is designed for higher altitudes is required.

Saturday, 15 December 2018

Info!! What Does Selv Hateful For Ability Supplies?

SELV stands for Safety Extra Low Voltage. Some AC-DC ability furnish installation manuals comprise warnings concerning SELV. For example, in that place may survive a alert most connecting 2 outputs inward serial because the resulting higher voltage may occur the defined SELV condom level, which is less than or equal to 60VDC. In addition, in that place may survive warnings most protecting the output terminals as well as other accessible conductors inward the ability furnish amongst covers to forestall them from existence touched past times operating personnel or accidently shorted past times a dropped tool, etc.

UL 60950-1 states that a SELV circuit is a “secondary circuit which is as well as therefore designed as well as protected that nether normal as well as unmarried error conditions, its voltages produce non occur a condom value.” H5N1 “secondary circuit” has no forthwith connectedness to the primary ability (AC mains) as well as derives its ability via a transformer, converter or equivalent isolation device.

Most switchmode depression voltage AC-DC ability supplies amongst outputs upwards to 48VDC encounter the SELV requirements. With a 48V output the OVP setting tin survive upwards to 120% of nominal, which would permit the output to laissez passer on 57.6V earlier the ability furnish shuts down; this would nonetheless accommodate to the maximum 60VDC for SELV power.

In addition, an SELV output is achieved through electrical isolation amongst double or reinforced insulation betwixt the primary as well as secondary side of the transformers. Moreover, to encounter SELV specifications, the voltage betwixt whatever 2 accessible parts/conductors or betwixt a unmarried accessible part/conductor as well as public must non occur a condom value, which is defined equally 42.4 VAC meridian or 60VDC for no longer than 200 ms during normal operation. Under a unmarried error condition, these limits are allowed to teach higher to 71VAC meridian or 120VDC for no longer than xx ms.

Don’t survive surprised if you lot notice other electrical specs that define SELV differently. The higher upwards definitions/descriptions cry to SELV equally defined past times UL 60950-1 as well as other associated specs regarding depression voltage ability supplies.

Info!! Should Ability Render Manufacturers Adopt Iec 62368-1:2014 Early On To Supersede Iec 60950-1 Together With Iec 60065?


In 2014 the IEC introduced edition two of the Hazard-Based Safety Engineering (HBSE) IEC 62368-1 standard.  Intended to supersede novel submittals for IEC 60950-1 too IEC 60065 inwards June 2019, it covers hazards too peril prevention for ITE (Information Technology Equipment) too well too visual equipment.
UL & CSA published the 2nd edition of the IEC 62368-1 criterion on Dec 1st, 2014, next Europe’s publication inwards September 2014.

The electrical flow standards are known equally “prescriptive” too closely command production design.  The novel criterion retains but about of those blueprint rules, but offers functioning options that powerfulness permit but about blueprint flexibility.  It must move stressed that dissimilar IEC 60601-1, a formal peril analysis is non required.  It is besides non a simpler merger of 60950-1 too 60065.
No appointment has been gear upward nevertheless for when “grandfathering” of the 60950-1 too 60065 standards ends.  It has been recommended past times but about exam regime that if a production is going to move removed from the marketplace past times 2018, too therefore create non function along alongside certifying to IEC 62368.  As in that location may move but about regions that cause got non accepted the novel standard, products that volition move on the marketplace afterward 2018 should expect at obtaining certification to IEC 62368, but maintain the existing 60950-1 too 60065 certifications.

Does this hateful that ability render manufacturers should outset transitioning over now?  No, the IEC commission recognizes this would impose a huge burden on everyone’s resources, including the certification bodies.  Clause 4.1.1 states that “Components too subassemblies that comply alongside IEC 60950-1 or IEC 60065 are acceptable equally purpose of equipment covered past times this criterion without farther evaluation other than to laissez passer on consideration to the appropriate utilisation of the component or sub-assembly inwards the destination product.”
One snippet of data I constitute this week; always wonder where the numbering convention of standards comes from?  If a criterion is IEC 50xxx it is based on a criterion of CENELEC (European Committee for Electrotechnical Standardization) origin.  If it is IEC 55xxx, it is based on CISPR (Special international commission on radio interference) origins.  For standards IEC 6xxxx, they originate from the IEC (International Electrotechnical Commission).
Power Guy

Friday, 14 December 2018

Info!! Iec/Ul/En 60950-1 Amendment 2

CENELEC (Comité Européen de Normalisation Électrotechnique) published what is believed to move the terminal alter to the EN 60950-1 touchstone inward August 2013.  60950-1 covers full general security requirements for Information Technology Equipment (ITE).  Commonly known equally “Amendment 2”, the security files volition forthwith mention to either EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 or EN 60950-1:2006/A2:2013.  The appointment of withdrawal is July 2nd, 2016 in addition to might render manufacturers are updating their files to the novel version of the standard.

UL & CSA announced their update to 60950-1 on Oct 14th, 2014, but dissimilar Europe, the Amendment two revision is non mandatory to existing files.  New products though are beingness certified to UL 60950-1, 2d Edition, 2014-10-14 in addition to CAN/CSA C22.2 No. 60950-1-07, 2d Edition, 2014-10.

This should move the terminal alter equally June 2019 volition encounter the motility to IEC 62368-1:2014 for both IEC 60950-1 in addition to IEC 60065.  The changes are considered equally mainly clarifications to polish that transition.  The security bodies bring commented on their websites that in that place would move minimal impact to might render manufacturers for Amendment 2.

The changes for almost might supplies for Amendment two are:

Any graphics used are to comply amongst ISO standards in addition to must move explained inward the installation manual.

Humidity testing has been introduced for equipment “designated for tropical regions”.  CCC & CQC certifications for China are already referring to this.

Similarly, to reverberate a mutual Chinese requirement for 5,000m operation, the add-on of a symbol volition dot if the equipment is to move operated at a maximum of 2,000m.  This is non an outcome for UL, EN or CB.

Non Pb acid batteries (with the exception of push cells) must comply amongst IEC 62133, in addition to volition solely behave on a real express issue of might supplies.

The purpose of VDRs - voltage dependant resistors – (a major alter for Edition 1), bring had a flammability requirement added.


As a note, all the self-certified Declarations of Conformity for CE marker volition bring to move re-written in addition to posted.

Info!! Ability Render Security Reports In Addition To Certifications


One tin detect a bully bargain of information on a might render yesteryear studying the manufacturer’s datasheet too other technical articles, but sometimes to a greater extent than information is required for the actual installation.  Where is this information?  It is inwards the might supply’s security reports too certifications.  Failure to review too follow these tin sweat delays when organisation certification is sought.

To run on this article simple, nosotros volition simply review a production that is certified to IEC 60950-1.

Usually in that place are iii principal documents; the CB certificate, an IEC 60950-1 CB study too / or EN 60950-1 essay out certificate too of class for North America, the UL or CSA 60950-1 essay out report.  Due to confidential information similar schematics, amount essay out reports are frequently restricted too may alone live on released amongst a non-disclosure understanding (NDA).  Fortunately reproduction is allowed yesteryear the essay out houses for the relevant pages of the report.

Usually the CB essay out certificate, which should ever accompany the CB essay out report, is simply ii or iii pages.  This is frequently world information too details the constituent numbers that own got been certified, their input too output ratings along amongst the security criterion (including revisions too amendments).  Its business office is to give a quick snapshot of the production too to present if all the certifications are current.  A production that has out of engagement certifications may alone live on suitable where the security bodies own got allowed the role of “grandfathering” for older systems, too volition non suitable for novel designs or major organisation upgrades.

To cut back cost, many might render manufacturers are using the CE Mark to dot compliance amongst EN 60950-1 rather than pay for too maintain a split upward EN 60950-1 essay out study too certificate.  In this illustration the CB essay out certificate (and CB essay out report) volition dot that the production was “additionally evaluated to EN 60950-1”.  This is perfectly acceptable.

Even an abridged CB or UL 60950-1 essay out study (the amount study may extend to over 300 pages) has useful information.  The department “Engineering Conditions of Acceptability” has the all-important details for how the production should live on used.

For example:

Are the outputs SELV?  Those outputs that are non should live on insulated or own got their access restricted to ensure that an operator or service technician cannot have an electrical shock.

Do whatever outputs own got hazardous liberate energy levels?  240VA is considered potentially unsafe if a screwdriver or metallic element item accidentally shorts them, too a encompass should live on installed to protect them.  Metal lookout straps own got caused serious burns to machine mechanics when they own got shorted the positive battery in conclusion to the car body.

Is “field wiring” allowed?  If not, whatever cabling has to live on attached yesteryear trained personnel.  Products similar DIN rails might supplies create let plain wiring too create non own got crimped wire terminations.

The maximum investigated branch circuit rating is given.  This reflects the size of the circuit breaker that was used during the security testing, specially when abnormal tests were performed.

The investigated Pollution Degree rating is stated.  A rating of 2 is normal for business office or laboratory equipment.  That production should non live on used where a pollution score of four is required for an exterior application where it may live on dependent area to rainfall.

Proper bonding to the end-product principal protective earthing resultant is listed every bit required or non required.  Failure to correctly world the production tin consequence inwards electrical shock.

The temperature shape of whatever magnetic cistron components is given.  Usually this is Class Influenza A virus subtype H5N1 (105oC) too organisation testing should banking concern tally to brand certain that is non exceeded nether worse illustration conditions.

“The next end-product enclosures are required:” Here the types of enclosures are indicated for mounting the might render in.  If an opened upward frame might render is beingness used, the study volition nation that it has to live on housed inwards an enclosure.

Other notes may live on listed, similar production orientation.
Many might render companies are forthwith posting this information on their website, along amongst the CE D of C (Declaration of Conformity); fifty-fifty simply about distributors are doing this too.  The recent surge of amendments to the standards though is keeping many webmasters busy!

Info!! An Update To The Transition From Iec 60950-1 To Iec 62368-1


On a weblog shipping service dorsum inward March 2015, I mentioned that a Hazard-Based Safety Engineering (HBSE) IEC 62368-1 measure volition live replacing IEC 60950-1 as well as IEC 60065, roofing hazards as well as gamble prevention for ITE (Information Technology Equipment) as well as well / visual equipment.

The transition appointment to EN 62368-1:2014 has at i time been extended eighteen months to Dec 20th, 2020 for novel submittals (or a pregnant change of the existing 60950/60065 file) inward the EU.  UL has too announced that the UL 62368-1 Edition No. 2 appointment is at i time Dec 20th, 2020. Influenza A virus subtype H5N1 issue of other countries accept adopted the standard, including Australia, Singapore, Malaysia, Nippon as well as Russia.  No exact appointment has been published for other countries similar China, Taiwan, Republic of Korea as well as Argentina.

The novel measure uses a Hazard Based Safety Engineering (HBSE) scientific discipline discipline, as well as operates inward 4 steps:

1.      Identifying energy sources inward the product

2.      Classifying the liberate energy for the potential of causing injury or harm

3.      Identify the necessary safeguards needed to protect from those energy sources

4.      Qualify the safeguards equally effective

The Energy Source ES classification handles the outcome on the trunk for a issue of hazards.  See Table 1 for lawsuit of the ii nearly relevant to ability supplies – electrical as well as thermal energy.

Energy Source class
Effect on the Body
Effect on combustible material
Class 1
Detectible, but non painful
Unlikely ignition
Class 2
Painful, but non an injury
Possible ignition, but limited
Class 3
An injury
Likely ignition, increment rapid & swift

Table 1 Energy Source classification

In addition, a iii someone scenario has been adopted for 62368-1 (see Table 2).            

Person
Description (See measure for total details)
Ordinary Person
A someone who is a user or is unopen yesteryear to the equipment
Instructed Person
A someone that is trained to position sources of hurting causing liberate energy as well as avoid them. Must non live exposed to injury causing liberate energy sources, fifty-fifty during a unmarried error condition
Skilled Person
A someone who has the preparation to recognize & avoid liberate energy sources that could crusade hurting or injury.  Must live protected against accidental contact alongside injury causing liberate energy sources

Table 2: Description of types of person


Depending on the Person type as well as the Energy Class, Safeguards accept to live inward house to protect that Person.  See Figure 1.



Figure 1: Protection for an Ordinary Person alongside dissimilar Energy Classes

As an example, i little alter ability render manufacturers may accept to brand to their designs to run into IEC 62369-1, concerns “capacitance discharge” of the air conditioning input. 

Figure 2 shows the typical schematic of an EMI filter department of a ability render as well as the location of a resistor that discharges the Line to Neutral X capacitors subsequently the air conditioning has been removed.  This avoids a user unplugging an air conditioning plug, touching the pins as well as getting an electrical shock.



Fig 2: EMI Filter Schematic

If the job cord was removed from the air conditioning plug at the peak of a 240V air conditioning cycle, as well as then the voltage would live 339Vdc.  The fourth dimension for that to decay to a rubber voltage depends upon the values of the X capacitor(s), the Line to Neutral resistor as well as whatsoever loading of the ability render converter circuitry.

IEC 60950-1 states that subsequently i bit that voltage has to live at a maximum of 42.4Vpk.  IEC 62368-1 states that for an X capacitance of 300nF or greater, subsequently ii seconds, the bound is 60Vpk inward normal status or 120Vpk inward a unmarried error condition.

A 10W ability telephone charger volition accept a rattling little X capacitance as well as a high value discharge resistor. Under 62368-1, if that resistor failed (a unmarried error condition) the ability render would belike nonetheless run into the 60Vpk status subsequently 2 seconds.  From Figure 1, this nonetheless complies alongside no Basic Safeguard is needed, fifty-fifty for an “Ordinary Person”.

A higher wattage ability render on the other hand, volition accept a much larger X capacitance.  With a unmarried error condition, the loss of the bleed resistor may resultant inward a voltage of greater than 120Vpk subsequently 2 seconds.  That would as well as then live an ES2 - Class 2 Energy Source - as well as from Figure 1, a Basic Safeguard would bespeak to live inward place.  Instead of only i bleed resistor, a bit i would bespeak to live added, inward parallel alongside the first.  The values of the resistor would live sized accordingly to ensure that the loss of one, would nonetheless discharge the X capacitor to a maximum of 120Vdc subsequently 2 seconds.

Supplementary Safeguards would live used inward other parts of the ability render circuit inward the same agency equally reinforced or double insulated is inward 60950-1.

One side outcome of the ES1 as well as ES2 limits is that IEC 62368-1 deems a 48V or fifty-fifty a 36V output ability render inward hiccup trend over electrical current equally an air conditioning output.  The ES1 limits for DC are 60V, but for upward to 1kHz that drops to 30Vrms or 42.2Vpk.  IEC 60950-1 recognizes that equally SELV, but nether the novel measure that would live ES2 as well as the output should non live made accessible to an Ordinary Person.  Pins as well as connectors non accessible yesteryear a blunt probe are exempt.

Power Guy

Info!! Mutual Security Standards Used Amongst Ability Supplies

A topic that comes upwards real regularly is what create the diverse security standards pertain to. Here is a brief listing of unremarkably used standards, the equipment that uses them, typical products too their purpose.

Base Standard Country (ies) Equipment Type Generic Product Types Purpose
CCC China Many Many Safety & Quality Mark
CE EU Voluntary annunciation based on miscellaneous standards Many Indicate conformity to standards
CSA 60950 CSA Information Technology Office machines, information & telecom networks, IT, Kiosks Protect against fire, electrical shock, injury
CSA60065 CSA Audio, Video too Similar Video, audio, projectors Protect against fire, electrical shock, injury
CSA60601 CSA Medical Electrical Surgical, monitoring, infirmary equipment Safety
CSA61010-1 CSA Measurement, Control too Laboratory Meters, Oscilloscopes Protect against fire, electrical shock, injury
EN50178 EU Power Power generation, ability installations Safety
EN55011 EU Industrial, scientific, too medical r-f Monitoring equipment, automation controls, measuring Limits too measuring of radio disturbance
EN55015 EU Lighting Lighting, LED lighting, street lighting Limits too measuring of radio disturbance
EN55022 EU Information Technology Office machines, information & telecom networks, IT, Kiosks Emission Limits (radiated too conducted)
EN60065 EU Audio, Video too Similar Video, audio, projectors Protect against fire, electrical shock, injury
EN60601 EU Medical Electrical Surgical, monitoring, infirmary equipment Safety
EN60950-1 EU Information Technology Office machines, information & telecom networks, IT, Kiosks Protect against fire, electrical shock, injury
EN61010-1 EU Measurement, Control too Laboratory Meters, Oscilloscopes Protect against fire, electrical shock, injury
Factory Mutual US Use inwards hazardous locations Oil refinery, petrochemical Protect against explosion
FCC Part 15 US Many Many Emission Limits (radiated too conducted)
ISA 12-12 US Use inwards hazardous locations Oil refinery, petrochemical Protect against explosion
REACH EU Many Many Registration, Evaluation, Authorization too restriction of Chemicals
SEMIF47 US Semiconductor fabrication Die manufacturing, wafer fabs Withstand dips inwards air-conditioning input
UL 60950 UL Information Technology Office machines, information & telecom networks, IT, Kiosks Protect against fire, electrical shock, injury
UL1310 UL Power Supplies DIN Rail, LED lighting, access controls, edifice automation Protect against fire
UL508 UL Industrial Control Process control, manufacturing flora automation Safety
UL60065 UL Audio, Video too Similar Video, audio, projectors Protect against fire, electrical shock, injury
UL60601 UL Medical Electrical Surgical, monitoring, infirmary equipment Safety
UL61010-1 UL Measurement, Control too Laboratory Meters, Oscilloscopes Protect against fire, electrical shock, injury
VCCI Japan Information Technology Office machines, information & telecom networks, IT, Kiosks Limits too measuring of RF emissions
VDE0805 Germany Information Technology Office machines, information & telecom networks, IT, Kiosks Protect against fire, electrical shock, injury

Let me know if this tabular array is helpful.

Info!! How Does The Novel Ul Order Touching On Me?

UL of late announced their offset Transcontinental Mark which denotes production compliance alongside European EN security standards equally good equally the CSA/UL/US Mark for the North American markets.  Basically, UL volition survive providing an “international security certification”.  And, this may impact European security houses similar TUV too others.  Here is what the novel international UL grade it looks like:

Although, at offset glance, this grade looks similar a “UL Listed” ability furnish certification alongside its encircled UL grade (as used for External Power Supplies), UL-EU confirmed that it too applies to stand-alone ingredient ability supplies similar those installed inward all electronic equipment.  Prior to this novel mark, the measure “component ability supply” UL grade for the USA too Canada looked similar this:

Some ability furnish manufacturers convey been reviewing purpose of UL to display the existing C-UL-US grade along alongside the self-declared CE mark.  The CE grade would survive backed upwards alongside an IEC60950-1 CB study equally documented proof of compliance.

It volition survive interesting to encounter how the European exam houses (e.g., TUV) react too if CSA responds alongside their ain version of this novel UL mark.

Info!! Course Of Written Report Two Or Course Of Written Report Ii Ability Supplies?

One enquiry I am oftentimes asked is: “The client is looking for a Class 2 ability supply; what tin y'all offering him?”

My reply is ever “Class 2” or “Class II (with Roman numerals)”, or both?  The interruption on the terminate of the band signifies an explanation is inwards order.

Class 2 is a classification referring to the NEC – National Electric Code.  To avoid potential cable overheating due to excessive currents in addition to electrical shock, the output of the ability render is express to 60VDC or 100VA, (100W when used amongst an AC-DC ability supply).  You volition often run across 24V output DIN track ability supplies or LED drivers rated at 91W rather than 100W because if the ability render is overloaded, whatever tolerance inwards the over electrical flow protection has to live on accounted for.

Often these products volition live on certified to UL1310 in addition to volition listing this inwards the datasheet.  An event of this is TDK-Lambda’s DSP series.  You tin run across from the model selector listing on page 2 of the DSP datasheet that output currents of 4.2A or greater are non approved to UL1310.

Class II (with Roman numerals) refers to ability supplies amongst either a double or reinforced insulation barrier betwixt the input in addition to the output. Class II supplies create non rely on an globe connexion to protect against stupor hazard. Many prison theatre mobile telephone band chargers in addition to laptop ability supplies are Class II.  TDK-Lambda’s DSP serial too are Class II, having simply a Line in addition to Neutral air-conditioning input without a dry reason connection.

H5N1 Class II ability render rating label volition exhibit this symbol:


One wages of Class II is amend surge protection betwixt input in addition to dry reason in addition to commonly a lower globe leakage current.

For to a greater extent than information virtually leakage current, delight run across unopen to other article virtually power render leakage electrical flow testing.

Thursday, 13 December 2018

Info!! What Is A Express Ability Source?

There are many technical details regarding Limited Power Sources (often referred to every bit an LPS) covered inwards the IEC60950-1 security standard, involving a diversity of applications, but I volition encompass but the basic aspects regarding AC-DC ability supplies inwards this weblog article.


Several security standards advert to IEC60950-1 for a broad hit of applications, too 1 of those referrals involves the role of Limited Power Sources.

What is, too why are Limited Power Sources important? Simply put, if a slice of electrical or electronic equipment supplying DC ability to external devices is to move installed yesteryear a tertiary party, such every bit an electrician, the peril of wiring fires & electrical stupor needs to move minimized. That electrician volition non move expected to know all the potential error scenarios too role the appropriate cable thicknesses too insulation to encompass those hazards. By using a Limited Power Source, the organisation wiring tin too move reduced, saving cost.

If a Limited Power Source is used, too thence the electrician’s chore is simplified, fifty-fifty if in that place is a (single) error within of the ability supply.

Some examples of testing that the ability provide manufacturer volition do, to induce upwards one's take away heed the maximum output electrical flow too ability encounter the “Limited Power Source” requirements are:
  1. Check the ability provide at maximum rated load
  2. Increase the charge of the ability provide until it is on the verge of overload
  3. Simulate an internal error yesteryear shorting the current-limiting resistor
  4. Short out the opto-coupler that provides feedback to the command loop
The weather for a “Limited Power Source” AC-DC ability provide are:

1. For a ability provide rated at 30V or less, the next must move met fifty-fifty amongst a unmarried error condition:
    a. The output electrical flow must non top 8A
    b. The output ability must non top 100W
2. For a ability provide rated to a higher house 30V, but non exceeding 60V:
    a. The output electrical flow must non top 150 ÷ Vout
    b. The output ability must non top 100W

This graph shows the limits for Limited Power Sources:




Taking some examples from TDK-Lambda’s DSP series of depression profile DIN track ability supplies:


 
The DSP60-5 is rated at 5V 7A – That would encounter (1b), but when lay into overload it would sure enough non encounter the (1a) boundary of 8A. This model is non listed every bit existence a Limited Power Source.

The DSP60-12 is rated at 12V 4.5A – Overload electrical flow would move unopen to 7A which meets (1a) too the maximum ability is 84W (12V x 7A) which too meets (1b). This model is listed every bit existence a Limited Power Source.

The DSP100-24 is rated at 24V 4.2A – Right out of gate this unit of measurement exceeds 100W, too thence it is non listed every bit a Limited Power Source.

The DSP100-24/C2 is rated at 24V 3.8A – This model truly has a exceptional electrical flow boundary & over ability circuit which strictly limits the output electrical flow too ability nether a error condition, thence it meets the <8A requirement of (b) too the boundary of <100W. Interestingly though, a unmarried error on the command circuit made the output ascent to 30.8V too thence it straight off falls nether the 30-60V boundary of 150 ÷ Vout = 4.8A maximum electrical flow (2b), which it passed. Therefore, this model is listed every bit a Limited Power Source.
 
Test results performed yesteryear the security bodies, such every bit UL, CSA or TUV, are usually constitute inwards the CB written report for the ability supply.
 

Info!! How Does Height Touching On Ac-Dc Ability Supplies?

Most AC-DC ability supplies that run into the security standards per UL/EN 60950-1 for ITE (Information Technology Equipment) applications are designed to run at typical percentage together with manufacturing flora altitudes, which tin vary from slightly inward a higher house ocean grade to equally high equally 2,000 meters (6,562 feet). And, many ability provide manufacturers provide units that are designed together with rated for performance at higher altitudes, upwards to 3,000 meters (9,843 feet) together with hence their supplies tin last used inward major cities located at higher elevations (e.g., Denver, Santa Fe, United Mexican U.S. of A. City, Bogota). Many broadcasting/communications stations/towers are located at altitudes upwards to 3,000 meters or higher inward lodge to maximize their range.

Altitude affects the blueprint of ability supplies since ‘air’ is used equally an electrical insulating medium (aka, dielectric) inward the structure of ability supplies, too equally nearly electronic devices. The density together with dielectric strength (insulating property) of air is real proficient at ocean level, merely at higher altitudes, the thinner air loses around of its dielectric strength, which needs to last compensated for. Switchmode ability supplies run off of high voltages (inputs of xc to 265Vac) together with internally generate fifty-fifty higher voltages (400Vdc or more), which withdraw to last insulated together with contained to forbid high voltage arcing or breakdown inside the supply, together with to protect the end-equipment together with operating personnel.

The drawing below shows a cross department of a typical printed circuit board (PCB), which is comprised of copper electrical conduction paths that our chemically etched on an insulated (dielectric) fiber board stuff (e.g., FR4, woven fiberglass fabric alongside epoxy resin), plus electronic components that are non shown inward this drawing. As tin last seen, the fiber board together with air, combined alongside the distances betwixt the etched conductive traces are the main insulation mediums for the circuit board.

Drawing Credits: Mammano B, ‘Safety Considerations inward Power Supply Design, Underwriters Laboratory / TI
  • The term ‘Clearance’ refers to shortage path betwixt the 2 conductive parts (circuit traces, components, etc.), measured through air.
  • The term ‘Creepage’ refers to the shortage path betwixt 2 conductive parts measured along the surface of the insulation (PCB, insulating materials/barriers, etc.).

What does this conduct maintain to create alongside altitude? Since ‘air’ gets thinner (reduced barometric pressure) at higher altitudes together with becomes less of an insulator, the PCB together with element layouts conduct maintain to last designed alongside sufficient security spacing distances to forbid high voltage arcs or breakdowns betwixt conductors and/or electronic components.

For example, typical ability provide blueprint exercise may permit 8 mm spacing distance betwixt main together with secondary circuits together with iv mm spacing distance betwixt main together with ground. These spacing distances volition vary depending upon the voltage levels betwixt conductors together with components together with the expected humidity, temperatures, pollution levels, together with attitudes.

For those ability products that must last approved per the Chinese CCC organization (required to export supplies into China), the novel Chinese Safety Standard GB 4943.1-2011, which is like to UL/EN 60950, requires strict specs for creepage together with clearance distances. As of Dec 1, 2012, the primary-to-secondary clearances must increment yesteryear a factor of 1.48 to qualify the provide for performance upwards to 5,000 meters, since many regions inward China are located at high altitudes. The option for CCC certified ability supplies is that they must clearly marked alongside a alert label that states that the ability provide must last used below 2,000 meters (see tabular array below).

The base of operations blueprint height for ITE ability supplies is 2,000 meters. However, equally mentioned before, equally the height increases, the air becomes a poorer insulator together with the spacing distances conduct maintain to last increased per the next tabular array (assuming an 8 mm clearance at 2000m).

Altitude (meters)Barometric Pressure (kPa)Multiplication Factor for ClearanceResulting Clearance (mm)
200080.01.008.00
300070.01,149.12
400062.01.2910.32
500054.01.4811.84

As tin last seen from this table, if a ability provide is to last operated at 5,000 meters, its conductor/components clearances must last increased yesteryear 48% compared to a provide designed for 2,000 meters.

The other major number of high altitudes on ability supplies is that the less dense air does non deport estrus equally well. To compensate for higher altitudes, ability supplies withdraw to last derated, or employ larger estrus sinks, or conduct maintain increased forced air flow, or a combination of these to insure proper cooling. In addition, the ability provide must last designed alongside the proper conductor together with element clearances equally discussed above.

In summary, whenever an application requires that a ability provide must run at altitudes inward a higher house 2,000 meters (6,562 feet), e'er cheque alongside the manufacturer to create upwards one's hear if this is acceptable, or if an alternate model that is designed for higher altitudes is required.

Info!! What Does Selv Hateful For Ability Supplies?

SELV stands for Safety Extra Low Voltage. Some AC-DC ability furnish installation manuals comprise warnings concerning SELV. For example, in that place may survive a alert most connecting 2 outputs inward serial because the resulting higher voltage may occur the defined SELV condom level, which is less than or equal to 60VDC. In addition, in that place may survive warnings most protecting the output terminals as well as other accessible conductors inward the ability furnish amongst covers to forestall them from existence touched past times operating personnel or accidently shorted past times a dropped tool, etc.

UL 60950-1 states that a SELV circuit is a “secondary circuit which is as well as therefore designed as well as protected that nether normal as well as unmarried error conditions, its voltages produce non occur a condom value.” H5N1 “secondary circuit” has no forthwith connectedness to the primary ability (AC mains) as well as derives its ability via a transformer, converter or equivalent isolation device.

Most switchmode depression voltage AC-DC ability supplies amongst outputs upwards to 48VDC encounter the SELV requirements. With a 48V output the OVP setting tin survive upwards to 120% of nominal, which would permit the output to laissez passer on 57.6V earlier the ability furnish shuts down; this would nonetheless accommodate to the maximum 60VDC for SELV power.

In addition, an SELV output is achieved through electrical isolation amongst double or reinforced insulation betwixt the primary as well as secondary side of the transformers. Moreover, to encounter SELV specifications, the voltage betwixt whatever 2 accessible parts/conductors or betwixt a unmarried accessible part/conductor as well as public must non occur a condom value, which is defined equally 42.4 VAC meridian or 60VDC for no longer than 200 ms during normal operation. Under a unmarried error condition, these limits are allowed to teach higher to 71VAC meridian or 120VDC for no longer than xx ms.

Don’t survive surprised if you lot notice other electrical specs that define SELV differently. The higher upwards definitions/descriptions cry to SELV equally defined past times UL 60950-1 as well as other associated specs regarding depression voltage ability supplies.

Info!! Should Ability Render Manufacturers Adopt Iec 62368-1:2014 Early On To Supersede Iec 60950-1 Together With Iec 60065?


In 2014 the IEC introduced edition two of the Hazard-Based Safety Engineering (HBSE) IEC 62368-1 standard.  Intended to supersede novel submittals for IEC 60950-1 too IEC 60065 inwards June 2019, it covers hazards too peril prevention for ITE (Information Technology Equipment) too well too visual equipment.
UL & CSA published the 2nd edition of the IEC 62368-1 criterion on Dec 1st, 2014, next Europe’s publication inwards September 2014.

The electrical flow standards are known equally “prescriptive” too closely command production design.  The novel criterion retains but about of those blueprint rules, but offers functioning options that powerfulness permit but about blueprint flexibility.  It must move stressed that dissimilar IEC 60601-1, a formal peril analysis is non required.  It is besides non a simpler merger of 60950-1 too 60065.
No appointment has been gear upward nevertheless for when “grandfathering” of the 60950-1 too 60065 standards ends.  It has been recommended past times but about exam regime that if a production is going to move removed from the marketplace past times 2018, too therefore create non function along alongside certifying to IEC 62368.  As in that location may move but about regions that cause got non accepted the novel standard, products that volition move on the marketplace afterward 2018 should expect at obtaining certification to IEC 62368, but maintain the existing 60950-1 too 60065 certifications.

Does this hateful that ability render manufacturers should outset transitioning over now?  No, the IEC commission recognizes this would impose a huge burden on everyone’s resources, including the certification bodies.  Clause 4.1.1 states that “Components too subassemblies that comply alongside IEC 60950-1 or IEC 60065 are acceptable equally purpose of equipment covered past times this criterion without farther evaluation other than to laissez passer on consideration to the appropriate utilisation of the component or sub-assembly inwards the destination product.”
One snippet of data I constitute this week; always wonder where the numbering convention of standards comes from?  If a criterion is IEC 50xxx it is based on a criterion of CENELEC (European Committee for Electrotechnical Standardization) origin.  If it is IEC 55xxx, it is based on CISPR (Special international commission on radio interference) origins.  For standards IEC 6xxxx, they originate from the IEC (International Electrotechnical Commission).