Saturday, 15 December 2018

Info!! Should Ability Render Manufacturers Adopt Iec 62368-1:2014 Early On To Supersede Iec 60950-1 Together With Iec 60065?


In 2014 the IEC introduced edition two of the Hazard-Based Safety Engineering (HBSE) IEC 62368-1 standard.  Intended to supersede novel submittals for IEC 60950-1 too IEC 60065 inwards June 2019, it covers hazards too peril prevention for ITE (Information Technology Equipment) too well too visual equipment.
UL & CSA published the 2nd edition of the IEC 62368-1 criterion on Dec 1st, 2014, next Europe’s publication inwards September 2014.

The electrical flow standards are known equally “prescriptive” too closely command production design.  The novel criterion retains but about of those blueprint rules, but offers functioning options that powerfulness permit but about blueprint flexibility.  It must move stressed that dissimilar IEC 60601-1, a formal peril analysis is non required.  It is besides non a simpler merger of 60950-1 too 60065.
No appointment has been gear upward nevertheless for when “grandfathering” of the 60950-1 too 60065 standards ends.  It has been recommended past times but about exam regime that if a production is going to move removed from the marketplace past times 2018, too therefore create non function along alongside certifying to IEC 62368.  As in that location may move but about regions that cause got non accepted the novel standard, products that volition move on the marketplace afterward 2018 should expect at obtaining certification to IEC 62368, but maintain the existing 60950-1 too 60065 certifications.

Does this hateful that ability render manufacturers should outset transitioning over now?  No, the IEC commission recognizes this would impose a huge burden on everyone’s resources, including the certification bodies.  Clause 4.1.1 states that “Components too subassemblies that comply alongside IEC 60950-1 or IEC 60065 are acceptable equally purpose of equipment covered past times this criterion without farther evaluation other than to laissez passer on consideration to the appropriate utilisation of the component or sub-assembly inwards the destination product.”
One snippet of data I constitute this week; always wonder where the numbering convention of standards comes from?  If a criterion is IEC 50xxx it is based on a criterion of CENELEC (European Committee for Electrotechnical Standardization) origin.  If it is IEC 55xxx, it is based on CISPR (Special international commission on radio interference) origins.  For standards IEC 6xxxx, they originate from the IEC (International Electrotechnical Commission).
Power Guy

Friday, 14 December 2018

Info!! An Update To The Transition From Iec 60950-1 To Iec 62368-1


On a weblog shipping service dorsum inward March 2015, I mentioned that a Hazard-Based Safety Engineering (HBSE) IEC 62368-1 measure volition live replacing IEC 60950-1 as well as IEC 60065, roofing hazards as well as gamble prevention for ITE (Information Technology Equipment) as well as well / visual equipment.

The transition appointment to EN 62368-1:2014 has at i time been extended eighteen months to Dec 20th, 2020 for novel submittals (or a pregnant change of the existing 60950/60065 file) inward the EU.  UL has too announced that the UL 62368-1 Edition No. 2 appointment is at i time Dec 20th, 2020. Influenza A virus subtype H5N1 issue of other countries accept adopted the standard, including Australia, Singapore, Malaysia, Nippon as well as Russia.  No exact appointment has been published for other countries similar China, Taiwan, Republic of Korea as well as Argentina.

The novel measure uses a Hazard Based Safety Engineering (HBSE) scientific discipline discipline, as well as operates inward 4 steps:

1.      Identifying energy sources inward the product

2.      Classifying the liberate energy for the potential of causing injury or harm

3.      Identify the necessary safeguards needed to protect from those energy sources

4.      Qualify the safeguards equally effective

The Energy Source ES classification handles the outcome on the trunk for a issue of hazards.  See Table 1 for lawsuit of the ii nearly relevant to ability supplies – electrical as well as thermal energy.

Energy Source class
Effect on the Body
Effect on combustible material
Class 1
Detectible, but non painful
Unlikely ignition
Class 2
Painful, but non an injury
Possible ignition, but limited
Class 3
An injury
Likely ignition, increment rapid & swift

Table 1 Energy Source classification

In addition, a iii someone scenario has been adopted for 62368-1 (see Table 2).            

Person
Description (See measure for total details)
Ordinary Person
A someone who is a user or is unopen yesteryear to the equipment
Instructed Person
A someone that is trained to position sources of hurting causing liberate energy as well as avoid them. Must non live exposed to injury causing liberate energy sources, fifty-fifty during a unmarried error condition
Skilled Person
A someone who has the preparation to recognize & avoid liberate energy sources that could crusade hurting or injury.  Must live protected against accidental contact alongside injury causing liberate energy sources

Table 2: Description of types of person


Depending on the Person type as well as the Energy Class, Safeguards accept to live inward house to protect that Person.  See Figure 1.



Figure 1: Protection for an Ordinary Person alongside dissimilar Energy Classes

As an example, i little alter ability render manufacturers may accept to brand to their designs to run into IEC 62369-1, concerns “capacitance discharge” of the air conditioning input. 

Figure 2 shows the typical schematic of an EMI filter department of a ability render as well as the location of a resistor that discharges the Line to Neutral X capacitors subsequently the air conditioning has been removed.  This avoids a user unplugging an air conditioning plug, touching the pins as well as getting an electrical shock.



Fig 2: EMI Filter Schematic

If the job cord was removed from the air conditioning plug at the peak of a 240V air conditioning cycle, as well as then the voltage would live 339Vdc.  The fourth dimension for that to decay to a rubber voltage depends upon the values of the X capacitor(s), the Line to Neutral resistor as well as whatsoever loading of the ability render converter circuitry.

IEC 60950-1 states that subsequently i bit that voltage has to live at a maximum of 42.4Vpk.  IEC 62368-1 states that for an X capacitance of 300nF or greater, subsequently ii seconds, the bound is 60Vpk inward normal status or 120Vpk inward a unmarried error condition.

A 10W ability telephone charger volition accept a rattling little X capacitance as well as a high value discharge resistor. Under 62368-1, if that resistor failed (a unmarried error condition) the ability render would belike nonetheless run into the 60Vpk status subsequently 2 seconds.  From Figure 1, this nonetheless complies alongside no Basic Safeguard is needed, fifty-fifty for an “Ordinary Person”.

A higher wattage ability render on the other hand, volition accept a much larger X capacitance.  With a unmarried error condition, the loss of the bleed resistor may resultant inward a voltage of greater than 120Vpk subsequently 2 seconds.  That would as well as then live an ES2 - Class 2 Energy Source - as well as from Figure 1, a Basic Safeguard would bespeak to live inward place.  Instead of only i bleed resistor, a bit i would bespeak to live added, inward parallel alongside the first.  The values of the resistor would live sized accordingly to ensure that the loss of one, would nonetheless discharge the X capacitor to a maximum of 120Vdc subsequently 2 seconds.

Supplementary Safeguards would live used inward other parts of the ability render circuit inward the same agency equally reinforced or double insulated is inward 60950-1.

One side outcome of the ES1 as well as ES2 limits is that IEC 62368-1 deems a 48V or fifty-fifty a 36V output ability render inward hiccup trend over electrical current equally an air conditioning output.  The ES1 limits for DC are 60V, but for upward to 1kHz that drops to 30Vrms or 42.2Vpk.  IEC 60950-1 recognizes that equally SELV, but nether the novel measure that would live ES2 as well as the output should non live made accessible to an Ordinary Person.  Pins as well as connectors non accessible yesteryear a blunt probe are exempt.

Power Guy

Thursday, 13 December 2018

Info!! Should Ability Render Manufacturers Adopt Iec 62368-1:2014 Early On To Supersede Iec 60950-1 Together With Iec 60065?


In 2014 the IEC introduced edition two of the Hazard-Based Safety Engineering (HBSE) IEC 62368-1 standard.  Intended to supersede novel submittals for IEC 60950-1 too IEC 60065 inwards June 2019, it covers hazards too peril prevention for ITE (Information Technology Equipment) too well too visual equipment.
UL & CSA published the 2nd edition of the IEC 62368-1 criterion on Dec 1st, 2014, next Europe’s publication inwards September 2014.

The electrical flow standards are known equally “prescriptive” too closely command production design.  The novel criterion retains but about of those blueprint rules, but offers functioning options that powerfulness permit but about blueprint flexibility.  It must move stressed that dissimilar IEC 60601-1, a formal peril analysis is non required.  It is besides non a simpler merger of 60950-1 too 60065.
No appointment has been gear upward nevertheless for when “grandfathering” of the 60950-1 too 60065 standards ends.  It has been recommended past times but about exam regime that if a production is going to move removed from the marketplace past times 2018, too therefore create non function along alongside certifying to IEC 62368.  As in that location may move but about regions that cause got non accepted the novel standard, products that volition move on the marketplace afterward 2018 should expect at obtaining certification to IEC 62368, but maintain the existing 60950-1 too 60065 certifications.

Does this hateful that ability render manufacturers should outset transitioning over now?  No, the IEC commission recognizes this would impose a huge burden on everyone’s resources, including the certification bodies.  Clause 4.1.1 states that “Components too subassemblies that comply alongside IEC 60950-1 or IEC 60065 are acceptable equally purpose of equipment covered past times this criterion without farther evaluation other than to laissez passer on consideration to the appropriate utilisation of the component or sub-assembly inwards the destination product.”
One snippet of data I constitute this week; always wonder where the numbering convention of standards comes from?  If a criterion is IEC 50xxx it is based on a criterion of CENELEC (European Committee for Electrotechnical Standardization) origin.  If it is IEC 55xxx, it is based on CISPR (Special international commission on radio interference) origins.  For standards IEC 6xxxx, they originate from the IEC (International Electrotechnical Commission).
Power Guy

Info!! An Update To The Transition From Iec 60950-1 To Iec 62368-1


On a weblog shipping service dorsum inward March 2015, I mentioned that a Hazard-Based Safety Engineering (HBSE) IEC 62368-1 measure volition live replacing IEC 60950-1 as well as IEC 60065, roofing hazards as well as gamble prevention for ITE (Information Technology Equipment) as well as well / visual equipment.

The transition appointment to EN 62368-1:2014 has at i time been extended eighteen months to Dec 20th, 2020 for novel submittals (or a pregnant change of the existing 60950/60065 file) inward the EU.  UL has too announced that the UL 62368-1 Edition No. 2 appointment is at i time Dec 20th, 2020. Influenza A virus subtype H5N1 issue of other countries accept adopted the standard, including Australia, Singapore, Malaysia, Nippon as well as Russia.  No exact appointment has been published for other countries similar China, Taiwan, Republic of Korea as well as Argentina.

The novel measure uses a Hazard Based Safety Engineering (HBSE) scientific discipline discipline, as well as operates inward 4 steps:

1.      Identifying energy sources inward the product

2.      Classifying the liberate energy for the potential of causing injury or harm

3.      Identify the necessary safeguards needed to protect from those energy sources

4.      Qualify the safeguards equally effective

The Energy Source ES classification handles the outcome on the trunk for a issue of hazards.  See Table 1 for lawsuit of the ii nearly relevant to ability supplies – electrical as well as thermal energy.

Energy Source class
Effect on the Body
Effect on combustible material
Class 1
Detectible, but non painful
Unlikely ignition
Class 2
Painful, but non an injury
Possible ignition, but limited
Class 3
An injury
Likely ignition, increment rapid & swift

Table 1 Energy Source classification

In addition, a iii someone scenario has been adopted for 62368-1 (see Table 2).            

Person
Description (See measure for total details)
Ordinary Person
A someone who is a user or is unopen yesteryear to the equipment
Instructed Person
A someone that is trained to position sources of hurting causing liberate energy as well as avoid them. Must non live exposed to injury causing liberate energy sources, fifty-fifty during a unmarried error condition
Skilled Person
A someone who has the preparation to recognize & avoid liberate energy sources that could crusade hurting or injury.  Must live protected against accidental contact alongside injury causing liberate energy sources

Table 2: Description of types of person


Depending on the Person type as well as the Energy Class, Safeguards accept to live inward house to protect that Person.  See Figure 1.



Figure 1: Protection for an Ordinary Person alongside dissimilar Energy Classes

As an example, i little alter ability render manufacturers may accept to brand to their designs to run into IEC 62369-1, concerns “capacitance discharge” of the air conditioning input. 

Figure 2 shows the typical schematic of an EMI filter department of a ability render as well as the location of a resistor that discharges the Line to Neutral X capacitors subsequently the air conditioning has been removed.  This avoids a user unplugging an air conditioning plug, touching the pins as well as getting an electrical shock.



Fig 2: EMI Filter Schematic

If the job cord was removed from the air conditioning plug at the peak of a 240V air conditioning cycle, as well as then the voltage would live 339Vdc.  The fourth dimension for that to decay to a rubber voltage depends upon the values of the X capacitor(s), the Line to Neutral resistor as well as whatsoever loading of the ability render converter circuitry.

IEC 60950-1 states that subsequently i bit that voltage has to live at a maximum of 42.4Vpk.  IEC 62368-1 states that for an X capacitance of 300nF or greater, subsequently ii seconds, the bound is 60Vpk inward normal status or 120Vpk inward a unmarried error condition.

A 10W ability telephone charger volition accept a rattling little X capacitance as well as a high value discharge resistor. Under 62368-1, if that resistor failed (a unmarried error condition) the ability render would belike nonetheless run into the 60Vpk status subsequently 2 seconds.  From Figure 1, this nonetheless complies alongside no Basic Safeguard is needed, fifty-fifty for an “Ordinary Person”.

A higher wattage ability render on the other hand, volition accept a much larger X capacitance.  With a unmarried error condition, the loss of the bleed resistor may resultant inward a voltage of greater than 120Vpk subsequently 2 seconds.  That would as well as then live an ES2 - Class 2 Energy Source - as well as from Figure 1, a Basic Safeguard would bespeak to live inward place.  Instead of only i bleed resistor, a bit i would bespeak to live added, inward parallel alongside the first.  The values of the resistor would live sized accordingly to ensure that the loss of one, would nonetheless discharge the X capacitor to a maximum of 120Vdc subsequently 2 seconds.

Supplementary Safeguards would live used inward other parts of the ability render circuit inward the same agency equally reinforced or double insulated is inward 60950-1.

One side outcome of the ES1 as well as ES2 limits is that IEC 62368-1 deems a 48V or fifty-fifty a 36V output ability render inward hiccup trend over electrical current equally an air conditioning output.  The ES1 limits for DC are 60V, but for upward to 1kHz that drops to 30Vrms or 42.2Vpk.  IEC 60950-1 recognizes that equally SELV, but nether the novel measure that would live ES2 as well as the output should non live made accessible to an Ordinary Person.  Pins as well as connectors non accessible yesteryear a blunt probe are exempt.

Power Guy