Monday, 17 December 2018

Info!! What Is Pfc In Addition To Why Produce Ane Necessitate It?

Switchmode might supplies without Power Factor Correction (PFC) tend to describe the air conditioning input electrical flow inward curt bursts or spikes relative to the work voltage, every bit shown inward Fig. 1. The Power Factor of a might render is technically the ratio of the existent might consumed to the apparent might (Voltsrms x Ampsrms) in addition to is a decimal betwixt 0 in addition to 1.0. If left uncorrected the Power Factor (PF) of switchmode supplies volition to a greater extent than oftentimes than non hold upwards unopen to 0.65 or less.


Switchmode might supplies without Power Factor Correction  INFO!! What is PFC in addition to why produce I necessitate it?
Figure 1. Input of switchmode might supplies without PFC. The voltage waveform is a sinewave in addition to the electrical flow waveform is a pulse or spike. PF<1 span="">

The Power Factor tin hold upwards improved yesteryear using PFC circuits. These circuits “smooth out” the pulsating air conditioning current, improving the PF, in addition to reducing the chances of a circuit breaker tripping prematurely. There are ii basic types of PFC, passive in addition to active. Passive PFC circuits are less expensive in addition to typically tin right the PF to nigh 0.85. Active PFC circuits are the most popular, are built into the switchmode might render in addition to tin increment the PF to 0.98 or higher. The closer the PF comes to beingness 1.0, the improve the functioning of the might supply. Ideally, nosotros desire to halt upwards alongside the input voltage in addition to electrical flow waveforms beingness sinusoidal in addition to inward stage alongside each other every bit shown inward Fig. 2.

Switchmode might supplies without Power Factor Correction  INFO!! What is PFC in addition to why produce I necessitate it?Figure 2. Voltage in addition to Current waveforms are sinusoidal in addition to in-phase. PF=1.

PFC is Required yesteryear International Regulations
An of import argue to accept PFC inward your might render is to comply alongside international regulations, specially if y'all intend to sell your equipment inward Europe. Since 2001, the European Union (EU) established limits on harmonic currents that tin look on the mains (AC line) of switchmode might supplies. Today, the most of import rule is the “European Norm” EN61000-3-2. This rule applies to might supplies alongside input might of 75 watts or greater, in addition to that trace upwards to sixteen amps off the mains. It sets severe limits on the harmonic currents upwards to the 39th, when measured at the input of switchmode might supplies.

For example, the offset harmonic is the primary input frequency, typically l Hz for the European Union countries. The 3rd harmonic is 150 Hz, in addition to the 39th harmonic is 1,950 Hz. These unwanted harmonic currents accept a straight human relationship to the Power Factor of switchmode might supplies. Therefore, might supplies that encounter EN61000-3-2 inherently accept high might factors that are typically 0.97 or higher.

PFC Increases the Supply’s Output Power Capability
The PF, much similar the supply’s efficiency rating, determines the amount of useful might a switchmode might render tin describe from the air conditioning work in addition to and then deliver to its output load. Specifically, the formula that determines this is:

VLrms x ILrms x PF x Eff = Pout

As an example, if a might render is operating off of 120VAC line, which is protected yesteryear 15A circuit breaker, UL guidelines state y'all should non describe to a greater extent than than 12A. So, using the formula above, nosotros tin compare ii might render examples alongside dissimilar Power Factors, every bit follows:

Example A: No PFC, PF = 0.65, 85% Efficiency, 120VAC input, 12A max. current:
Therefore: 120VAC x 12A x 0.65 x 0.85 = 796 Watts Output Power

Example B: PFC used, PF=0.98, 85% Efficiency, 120VAC input, 12A max. current:
Therefore: 120VAC x 12A x 0.98 x 0.85 = 1200 Watts Output Power

As tin hold upwards seen above, the might render inward Example B (with PFC) tin deliver 404 Watts or 51% to a greater extent than might to its output charge than the non-PFC supply, a pregnant increase.

Why produce I necessitate PFC?
Influenza A virus subtype H5N1 might render alongside PFC tin render higher output charge currents than those without PFC. PFC significantly reduces the air conditioning electrical flow harmonics, leaving mainly the “fundamental” electrical flow frequency that is in-phase alongside the voltage waveform (Fig. 2). International regulations dictate the substantial reduction of harmonic currents. The vast bulk of AC-DC might supplies manufactured yesteryear Lambda Americas has active PFC, is inward accordance alongside EN61000-3-2 in addition to provides typical might factors inward the make of 0.97 to 0.99.

Info!! Benefits Of Environmentally Friendly Ability Supplies

Increasingly, Lambda’s customers are quest for too receiving Environmentally Friendly (EF) or “Green” ability supplies. What constitutes an EF/Green ability supply? There are a release of factors which contribute to a ability render beingness considered EF/Green. These include: RoHS compliance, electrical dissonance (EMI) suppression, high efficiency too ability factor correction (PFC).

RoHS Compliance: Lead, mercury too other “hazardous” elements too chemicals used inwards the production of electronic devices bring been identified, too by-law (since July 2006), bring been banned or severely express to their content inwards these devices, past times the European Union (EU). These limitations are spelled out inwards what is called the RoHS Directives (Restriction of Hazardous Substances). Currently, all products sold to the countries inside the European Union must comply amongst the RoHS Directives. Many of U.S.A. hither inwards America bring adopted like restrictions. Lambda has been a leader inwards providing RoHS-compliant ability supplies fifty-fifty to their U.S.A. customers who may non currently require them. This represents Lambda’s dedication to making the the world a greener too cleaner house to live. Over 99% of Lambda’s ability products are RoHS-compliant amongst a few exceptions beingness for those industries that are RoHS-exempt such equally specific armed services applications.

EMI Suppression: All electrical devices contribute inwards some agency to the electrical dissonance that “pollutes” our ability lines too airways inwards the flat of unwanted dissonance spikes too radio interference. These unwanted dissonance generators are restricted to the amount of EMI (Electro-Magnetic Interference) they are allowed to emit past times strict standards that are produced too maintained past times the FCC too international organizations (e.g., IEC, EN). Power supplies are amid the electrical devices that bring an inherent electrical dissonance occupation (both conducted too radiated) which must travel addressed past times the ability render designer too manufacturer. Without properly designed internal EMI filters too RF shielding, ability supplies would piece of work huge polluters of our electrical too electronic environment. Lambda ability supplies comply amongst the close rigorous EMI suppression standards. For example, the really restrictive FCC Class-B EMI compliance is available, equally standard, on many Lambda ability supplies.

High Efficiency: The efficiency rating of a ability render is measured past times comparison the AC ability going into the ability render divided past times the DC ability coming out of the supply. For example, if 100 watts of AC ability is used past times a ability render for it to provide ninety watt of DC output power, the efficiency of the render is calculated past times dividing 90W past times 100W, which equals 0.90 or 90% efficiency. When comparison a 75% to a 90% efficient ability supply, the savings inwards electricity usage too wasted loose energy (in the flat of heat) is quite significant.

Power Factor Correction (PFC): Modern switchmode ability supplies should include active Power Factor Correction circuits inwards companionship to maximize the AC ability that is used past times the supply. The Power Factor of a ability render is technically the ratio of the existent ability consumed to the apparent ability (Volts-rms x Amps-rms) too is a decimal release betwixt 0 too 1.0. If left uncorrected the Power Factor (PF) of switchmode supplies volition to a greater extent than frequently than non travel some 0.65 or less. With active PFC, switchmode ability supplies tin dismiss arrive at ability factors from 0.96 to 0.99. Without PFC, switchmode supplies would describe their AC occupation electrical flow inwards the flat of spikes or pulses, instead equally a build clean sinewave; the cyberspace termination beingness that the AC ability wires, circuit breakers too ability generating plants demand to travel sized larger than if they are driving products that comprise PFC ability supplies.

So what does High Efficiency too PFC hateful relative to beingness Environmentally Friendly?
Most electricity used inside the USA is generated past times burning fossil fuels such equally oil, natural gas or coal. It has been shown that in that place is a green-house-effect that is increasing at an alarming charge per unit of measurement due to the large amount of carbon dioxide that ability generation plants produce. So, whenever nosotros tin dismiss trim down the amount of electricity used, nosotros are contributing to a cleaner environment, a reduction of CO2 inwards the atmosphere too our dependence on, too the shipping costs of unusual crude from the OPEC countries (the crude tankers burn downwards diesel fuel, which farther adds to the pollution).

In addition, in that place tin dismiss travel meaning coin savings to the ability render user. Basically the savings of only 1-watt dissipated inwards the ability render = 365 days x 24 hrs x 1W = 8.76kW/hrs per year. If electricity costs $0.30 per kW/hr, that would amount to $2.63/year per each watt saved. If nosotros boost the efficiency of a ability render past times alone 5% on a 150W unit of measurement from 85% to 90%, that saves 7.5W [(150W x 0.15 = 22.5W) - (150 x 0.10 = 15W) = 7.5W]. That translates to $19.73 per twelvemonth savings (7.5W x $2.63/year = $19.73/year), which is to a greater extent than than the buy toll of the ability render over its typical lifespan (4 to v years), plus, nosotros bring reduced the amount of carbon dioxide inwards the air. If nosotros reckon an OEM who uses a 90% efficient ability render (instead of 85%) inwards their destination production too produces 100,000 units/year, the “total electrical ability savings” would amount to 100,000 units x 7.5W = 750,000 watts per hour, a meaning ability savings.

Furthermore, the higher the efficiency of the ability supply, the less ability is wasted inwards the render too the less loose energy is needed to withdraw that wasted loose energy (in the flat of heat), past times cooling the render or the room inwards which the equipment is used (via role of electromechanical fans, blowers, air conditioning, etc). The combination of high efficiency too PFC inwards ability supplies allows the role of smaller guess ability distribution wires, lower-rated circuit breakers too fewer ability generating plants (air polluters).

s customers are quest for too receiving Environmentally Friendly  INFO!! Benefits of Environmentally Friendly Power SuppliesLambda’s HWS Series, 1000-Watt Switchmode Power Supply is fully RoHS-Compliant, Meets FCC Class B EMI, has integral active PFC (Power Factor =0.98) too has a typical operating Efficiency of 88%.

In Summary: As mentioned above, in that place are many factors that comprise an “environmentally friendly/green” ability supply. And, the benefits to the end-user are significant. Lambda is a leader inwards the provision of these advanced ability devices too our international presence insures that nosotros volition piece of work on to travel at the forefront of these “Green & Clean” ability products.

Info!! Harvesting To A Greater Extent Than Liberate Energy Without Edifice To A Greater Extent Than Ability Plants

An AC-DC switch-mode ability render without Power Factor Correction (PFC) tin delineate roughly 950 Watts from a typical 115VAC wall socket protected yesteryear a 15A circuit breaker earlier exceeding the UL mandated bound of 12A. Influenza A virus subtype H5N1 unproblematic charge similar a toaster tin delineate almost 1400 Watts. The divergence betwixt the 2 is due to the higher Power Factor (PF) of the toaster, which presents a resistive charge to the ability line. If nosotros right the Power Factor of the switchmode render it tin together with so delineate close every bit much ability every bit the toaster, allowing it to provide to a greater extent than output ability to its charge from the same 115VAC/15A wall socket.

What is Power Factor Correction (PFC)?
Power Factor (PF) is technically the ratio of existent ability consumed to the apparent ability (Volts-RMS x Amps-RMS), together with is expressed every bit a decimal fraction betwixt 0 together with 1. PF is traditionally known every bit the stage divergence betwixt sinusoidal voltage together with electrical flow waveforms. When the air-conditioning charge is partly capacitive or inductive, the electrical flow waveform is out of stage alongside the voltage (Fig. 1, the dotted line of piece of occupation is the electrical flow waveform). This requires additional air-conditioning electrical flow to hold out generated that isn't consumed yesteryear the load, creating wasted I2R (wattage) losses inwards the ability lines.

An electrical motor is inductive, specially when it is starting. The electrical flow waveform lags behind the voltage waveform, dropping the PF to good below 1 (similar to Fig. 1). This is why many motors accept “starting” capacitors installed to counteract the inductance, together with hence right the PF during motor startup.

mode ability render without Power Factor Correction  INFO!! Harvesting More Energy without Building More Power Plants
Figure 1. Voltage together with electrical flow waveforms are sinusoidal but out-of-phase; PF <1 .="" span="">

Influenza A virus subtype H5N1 unproblematic resistive charge has the highest PF of 1. An air-conditioning voltage across the resistor causes an air-conditioning electrical flow which is identical to together with in-phase alongside the voltage waveform (Fig. 2).

mode ability render without Power Factor Correction  INFO!! Harvesting More Energy without Building More Power PlantsFigure 2. Voltage together with Current waveforms are sinusoidal together with in-phase; PF=1.

Influenza A virus subtype H5N1 switchmode ability render when viewed every bit an air-conditioning charge is neither capacitive nor inductive, but non-linear. Influenza A virus subtype H5N1 switchmode render conducts electrical flow inwards curt pulses or spikes that are in-phase alongside the line of piece of occupation voltage (Fig. 3). The production of “Volts-RMS x Amps-RMS” is considerable higher than the existent ability consumed, together with thus the PF is much less than 1, typically about 0.65 or less.

mode ability render without Power Factor Correction  INFO!! Harvesting More Energy without Building More Power PlantsFigure 3. Voltage waveform is sinusoidal, electrical flow waveform is non-sinusoidal but in-phase; PF<1 .="" br="">

Improving the Power Factor
Low Power Factors tin hold out improved via Power Factor Correction (PFC) circuits. The types used for switchmode ability supplies “smooth out” the pulsating air-conditioning current, lowering its RMS value, improving the PF together with reducing the chances of a circuit breaker tripping. There are 2 basic types of PFC: Active together with Passive. Active PFC is to a greater extent than effective, a fleck to a greater extent than expensive, to a greater extent than oftentimes than non integrated into the switchmode ability supply, together with tin accomplish a PF of close 0.98 or better. Passive PFC is less expensive together with typically corrects the PF to close 0.85.

Harvesting Additional Output Power
To create upwards one's heed only how much to a greater extent than ability is available from the air-conditioning line of piece of occupation together with a ability render alongside PFC, the user needs to sympathise the next equation, which defines the amount of output ability (Pout) available from a switchmode supply:

Pout = VL-RMS x IL-RMS x PF x Eff

For example, UL limits a system's line of piece of occupation electrical flow to 80% of the circuit breaker's rating. For a typical 15A breaker, 12A is the maximum allowed, together with the best-case ability available is hence 120VAC x 12A = 1440 Watts. Referring to the higher upwards equation, hither are 2 examples of supplies alongside dissimilar ability factors:

  • A switch-mode render alongside 0.65 PF together with 85% efficiency tin entirely deliver (120 x 12 x 0.65 x 0.85) = 796 Watts (Pout).
  • However, if the ability component is corrected to 0.98, the same ability render tin at nowadays deliver (120 x 12 x 0.98 x 0.85) = 1200 Watts (Pout), a 51% increase.

From the examples above, it tin hold out seen that yesteryear employing ability supply’s alongside PFC, to a greater extent than output ability tin hold out delivered to the OEM’s end-product, without the involve to increment the air-conditioning ability wire sizes, increment the circuit breaker’s rating or delineate to a greater extent than electrical flow from the ability plants. Thus, PFC has a pregnant outcome on our environs relative to reducing the pollutants coming from electrical ability plants.

Meeting International Regulations
Since switchmode ability supplies without PFC tend to delineate the air-conditioning line of piece of occupation electrical flow inwards a non-linear fashion, many unwanted harmonic currents are generated together with reflected dorsum on the air-conditioning ability lines. These reflected harmonic currents are “pollutants” to the ability grid that accept a negative deport upon on other devices connected to the same ability lines. These unwanted harmonic currents tin hit inwards frequency from the 100 Hz on upwards to over 2,000 Hz, together with accept a straightaway human relationship to the Power Factor of switchmode ability supplies.

An of import argue to accept PFC inside your ability render is to comply alongside international regulations, specially if yous recollect to sell your equipment inwards Europe. Since 2001, the European Union (EU) established limits on harmonic currents that tin look on the mains (AC line) of switchmode ability supplies. These regulations were position inwards house to maximize the available ability generated each hateful solar daytime yesteryear electrical ability plants located worldwide. The intent was to brand the most of the ability nosotros accept today without expanding our carbon footprint. Today, the most of import rule is the “European Norm” EN61000-3-2. This rule applies to ability supplies alongside input ability of 75 watts or greater, together with that delineate upwards to sixteen amps off the mains. It sets severe limits on the harmonic currents upwards to the 39th, when measured at the input of switchmode ability supplies. Power supplies alongside PFC circuits that encounter EN61000-3-2 inherently accept high ability factors that are typically 0.97 or better.

Summary
As previously mentioned, "Power Line Harmonics" are created whenever the line of piece of occupation electrical flow is non a pure sinewave, every bit is the instance alongside a switchmode ability supply's input, which tend to accept “pulsed” currents (Fig 3). Measuring ability line of piece of occupation harmonics is a mathematical way to delineate a complex waveform's Power Factor yesteryear resolving it into a key frequency together with its many harmonics.

The harmonic currents produce non contribute to the output charge power, but campaign unwanted heating inwards the wall socket, wiring, circuit breaker, together with distribution transformers, resulting inwards wasted energy. When personal computers outset hitting the mainstream market, their ability supplies lacked PFC. As a result, circuit breakers that seemed to hold out sized correctly for the charge were tripping for no apparent reason. After investigation, it was determined that the misfortunate ability component of the PC’s ability supplies was the culprit.

Today novel “green initiatives” are dictating that personal computers include ability supplies which must accept Power Factor Correction (PFC) together with high efficiencies. PFC significantly reduces harmonics, resulting inwards almost a pure “fundamental” electrical flow frequency that volition hold out in-phase alongside the voltage waveform (Fig. 2). International regulations dictate the substantial attenuation of harmonic currents. The vast majorities of AC-DC ability supplies manufactured yesteryear TDK-Lambda Americas employ active PFC, are inwards accordance alongside EN61000-3-2 together with provide typical ability factors inwards the hit of 0.97 to 0.99.


mode ability render without Power Factor Correction  INFO!! Harvesting More Energy without Building More Power Plants

Info!! What Is The Semi F47 Business Sag Spec All About?

We accept all seen lights dim at habitation or at function in addition to this is an indication that the air conditioning describe of piece of employment voltage has been reduced or sagged. Although an occasional dimming of lights tin last tolerated, when it comes to manufactory automation equipment, describe of piece of employment sag tin last the origin of a production shutdown, resulting inwards meaning revenue losses. Since the production of semiconductors, including microprocessors, is a really precise in addition to expensive process, dorsum inwards 1999 the Semiconductor Equipment in addition to Materials Institute (SEMI), established standards relative to air conditioning describe of piece of employment sag immunity. This specification is called the SEMI F47 Voltage Sag Immunity Standard in addition to has been revised periodically. Because many other manufactory automation processes are as critical, some of these production products ask to comply alongside the SEMI F47 measure as well.

We accept all seen lights dim at habitation or at function in addition to this is an indication that the air conditioning describe of piece of employment  INFO!! What is the SEMI F47 describe of piece of employment sag spec all about?
Basically, this measure requires that the AC-DC ability render that is used inwards semiconductor production, or inwards other manufactory automation equipment, proceed to provide the required output voltage in addition to current, fifty-fifty if the input voltage dips below its specified limits. As tin last seen inwards the nautical chart below, inwards the bluish area, the basic specs require that the ability render perform usually fifty-fifty if the input voltage sags downward to 50% of its nominal voltage for upwards to 200 ms, or sags to 70% for upwards to 500 ms, in addition to sags to 80% for upwards to i second. Since this sag per centum refers to the nominal describe of piece of employment voltage, this agency for illustration that alongside a nominal 220VAC input, the air conditioning voltage tin sag downward to 50% or 110VAC for upwards to 200 ms, downward to 70% or 154VAC for 500 ms, in addition to downward to 80% or 176VAC for upwards to i second.

We accept all seen lights dim at habitation or at function in addition to this is an indication that the air conditioning describe of piece of employment  INFO!! What is the SEMI F47 describe of piece of employment sag spec all about?
There are additional sag ride-through “recommendations” inside the latest version of the standard, which is the SEMI F47-0706 (these recommendations are non requirements) that includes functioning of the ability render alongside 0% input ability (no power) for upwards to xx ms. This recommendation tin last accommodated past times insuring the selected ability render has a “hold-up time” specification of xx ms or longer. Other newly recommended thresholds inside the SEMI F47-0706 include sags of 80% for 10 seconds, in addition to continuous sags of 90%. Most ability supplies that consider the previous versions of this standard, the SEMI F47-0200, in addition to accept a hold-up spec of xx ms or greater, should last able to consider the novel recommendations (not requirements) as well.

The simplest in addition to lowest toll method of complying alongside the SEMI F47 measure is to role a ability render alongside a universal input, such as ninety to 264VAC, in addition to operate it from a 220VAC or higher describe of piece of employment input. In this way you lot automatically consider in addition to move on the measure since this type of ability render tin operate downward to 90VAC (even lower than the 50% describe of piece of employment sag spec of 110VAC). Note that this method does apply to auto-strap ability supplies.

Another way of coming together the SEMI F47 is to depict less ability than the render tin usually provide (de-rate the supply). If you lot create this, ever banking concern friction match alongside the manufacturer to confirm that your reduced charge volition let the render to fully consider the SEMI F47 standard. This may require extra testing to confirm compliance, either past times the ability render manufacturer or the end-product OEM. Alternatively, the ability render manufacturer may last able to alter the render to consider the SEMI F47 standard.

Some manufactory automation equipment require the role of SEMI F47 “certified” ability supplies, which agency the supplies were tested past times an exterior agency or laboratory in addition to found to fully comply alongside the measure (similar to UL certification). If this is a requirement, ever await for supplies that accept existing certifications from a reliable manufacture, because the toll of getting this type of certification tin amount to $2,000 or more. There is a granddad clause inwards the updated standards that provides for equipment that was tested or certified nether the previous versions of the measure to non require re-testing or re-certification.

Many industrial-type ability supplies are designed and/or certified to consider the SEMI F47. These supplies may last a fighting to a greater extent than expensive, simply it volition last the lowest toll solution, particularly if you lot compare it to the toll of adding an external constant voltage transformer or UPS to the input of the ability supply.

Power render manufacturers such as TDK-Lambda offering supplies that are SEMI F47 certified in addition to supplies that operate alongside a broad universal input of ninety to 264VAC. In addition, modified supplies tin last provided that consider this in addition to other prevailing ability render specifications.

Info!! Ce Rank Together With Dc-Dc Converters

The CE identification score is accepted across the entire European Community. It is an indication that the production to which it is applied to conforms amongst the minimum requirements of all the applicable European Directives for that product, too that duly authorized assessment procedures (technical files) cause got been carried out on that product.

The nearly mutual ability provide Directive is the Low Voltage Directive (LVD), EC release 73/23/EEC, which came into forcefulness inward 1973. This applies to all electrical equipment amongst an air-conditioning input voltage of betwixt l too one thousand V for alternating electrical flow too betwixt 75 too 1500 V for at 1 time current.

Many DC-DC board mountain converters are thus exempt from this directive if they cause got a nominal input voltage of 5VDC, 12VDC or 24VDC provided the input arrive at is non 75VDC or higher.

Most 48V input DC-DC converters cause got a DC input arrive at of 36V to 75VDC too and then autumn nether the Directive. four : 1 input arrive at models (18 - 75VDC) would likewise hold out covered.

Influenza A virus subtype H5N1 link to the LVD tin hold out institute hither http://ec.europa.eu/enterprise/electr_equipment/lv/index.htm


Update:  The CE score at nowadays covers RoHS2, too then the mark volition apply to lower input voltage converters

Info!! Ability Render Efficiency – How Of Import Is It?

ENERGY STAR®’s conclusion to “sunset” programs for EPSs (External Power Supplies), as well as applications using them, has raised the query “Does this hateful that ability render efficiency is no longer a concern?”

In a mainly cost driven ability render market, production marketing is oft challenged during a novel production draw of piece of job organization innovation review, regarding the need for high efficiency on the production specification.

The biggest requestor of high efficiency ability supplies are the manufacturers of large information centers, primarily because of the huge amount of electricity they consume.  In 2007 the EPA estimated that the national annual electricity cost for servers as well as information centers could last a staggering $7.4 billion inwards 2011.

Power render manufacturers convey been told yesteryear information middle producers that they are willing to pay (a little) to a greater extent than for higher efficiency products, because the operators are aware that the ROI is quite short.  TDK-Lambda besides is participating inwards the evaluation as well as piece of job of DC ability systems. 

DC ability systems for information centers piece of job upwards to 15% less ability yesteryear removing i or to a greater extent than conversion phase yesteryear supplying 380VDC to the servers rather than high voltage AC.

Current UPS Backed-up System



DC Bus System

The the U.S. of A. authorities has had the eighty Plus programme inwards house for servers as well as computers for a discover of years amongst a multifariousness of efficiency levels ranging from a basic degree to “platinum”.

In consumer electronics where although the ability depict is quite pocket-size (particularly inwards standby), in that location are 100s of millions of devices deployed (laptop ability supplies, telephone & photographic television set camera chargers & LCD TVs to hollo a few) as well as the overall liberate energy usage is considerable.  The top dog drivers for efficiency improvement are the soil as well as utility companies, because of the cost as well as fourth dimension to construct novel ability stations.  The average consumer is non that concerned equally it volition non dramatically acquit upon their electricity bill.

As an industrial ability render manufacturer, TDK-Lambda is beingness asked yesteryear unopen to customers for higher efficiency ability supplies.  These customers are selling to halt users similar hospitals or large retailers who are going "green".  Where the purchaser is non beingness mandated to cut back liberate energy consumption or is driven yesteryear price, the efficiency “sell” unremarkably fails.

TDK-Lambda's R&D is real focused on developing higher efficiency ability supplies, driven yesteryear what nosotros run into equally a futurity marketplace as well as TDK's inaugural on environmental consciousness.  Current high efficiency products include the novel EFE serial of ability supplies that characteristic 90% efficiency using digital control.  http://us.tdk-lambda.com/lp/products/efe-series.htm.


TDK-Lambda besides supplies 2 of the major automotive manufacturers the DC-DC converters for hybrid electrical vehicles as well as is developing novel products for a host of upcoming electrical cars.  Efficiency standards of automobiles is something that the purchaser understands, primarily because of the cost of running a vehicle is significant.

Sunday, 16 December 2018

Info!! Novel Requirements For Ce Mark On Ability Supplies

I idea I would part to a greater extent than or less upcoming legislation changes regarding the CE grade for might supplies.
Currently the CE grade is applied to “embedded might supplies” (supplies installed inwards end-users equipment) that encounter the Low Voltage Directive 2006/95/EC. Assurance of conformance is commonly backed past times compliance to EN60950-1.

Non-embedded units similar external might adapters or DIN rails might supplies convey to comply amongst the EMC Directive 2004/108/EC inwards improver to the Low Voltage Directive. Compliance is backed past times testing to the immunity standards described inwards EN61000.

DC-DC converters that run amongst a DC input of less than 75V were exempt from CE marking, a discipline of my 2009 weblog post.

On Jan 2nd, 2013, the CE legislation changes! In July 2011, the Recast RoHS Directive was published, in addition to adjacent twelvemonth becomes enforceable. The half-dozen hazardous in addition to restricted substances originally covered past times RoHS stay the same, which is proficient for manufacturers.
Prior to the recast, this was applicable to eight production categories:
  • Large occupation solid appliances
  • Small occupation solid appliances
  • IT & Communications equipment
  • Consumer equipment
  • Lighting equipment
  • Electrical & electronic tools
  • Toys, leisure in addition to sports equipment
  • Automatic dispensers

Post recast, 5 to a greater extent than categories convey been added (but non immediately):
Medical devicesJuly 2014
In-Vitro Diagnostic devicesJuly 2016
Monitoring & Control InstrumentsJuly 2014
Industrial Monitoring & Control instrumentsJuly 2017
All other electrical & electronic equipmentJuly 2019

To apply a CE grade to a product, 1 must convey proof of compliance available; it is insufficient to say, “to the best of our cognition our products are compliant”. I convey read articles inwards the press that random testing for RoHS compliance has uncovered that a large per centum of consumer products failed to encounter the standard. By including RoHS into the CE grade gives the European Union the might to severely penalize importers of non-compliant product.

Power provide manufacturers are at nowadays updating their Declaration of Conformance documents (D of Cs) to include RoHS.
One other touching is that the previously exempt depression voltage input DC-DC converters (<75VDC) volition at nowadays convey to convey the CE grade applied to request compliance (just for the RoHS).  This volition non hold out a occupation equally almost manufacturers convey already converted their manufacturing over for electrical current products.

Saturday, 15 December 2018

Info!! Ul 60601-1 Too Ansi/Aami Es 60601-1


On datasheets for novel medical ability supplies, yous mightiness discovery that at that spot is no advert of UL 60601-1, only a novel security touchstone called ANSI/AAMI ES 60601-1:2005 is existence called out.

So what has happened?  ES 60601-1 is inwards fact identical to IEC 60601-1 only amongst U.S. deviations to comply amongst U.S. National Electric Code.  UL is instantly using that touchstone to write their reports together with is the touchstone used inwards the United States of America to comply to the 3rd edition.

The FDA instantly officially recognizes ANSI/AAMI ES 60601-1:2005 inwards the Federal Register

Older ability supplies are calling upwards this novel standard, together with volition likewise reference the older UL 60601-1 standards to give-up the ghost along continuity for existing customers amongst UL’s “grandfather” clause.

ANSI is the American National Standards Institute.  AAMI is the Association for the Advancement of Medical Instrumentation.
Power Guy

Info!! Should Ability Render Manufacturers Adopt Iec 62368-1:2014 Early On To Supersede Iec 60950-1 Together With Iec 60065?


In 2014 the IEC introduced edition two of the Hazard-Based Safety Engineering (HBSE) IEC 62368-1 standard.  Intended to supersede novel submittals for IEC 60950-1 too IEC 60065 inwards June 2019, it covers hazards too peril prevention for ITE (Information Technology Equipment) too well too visual equipment.
UL & CSA published the 2nd edition of the IEC 62368-1 criterion on Dec 1st, 2014, next Europe’s publication inwards September 2014.

The electrical flow standards are known equally “prescriptive” too closely command production design.  The novel criterion retains but about of those blueprint rules, but offers functioning options that powerfulness permit but about blueprint flexibility.  It must move stressed that dissimilar IEC 60601-1, a formal peril analysis is non required.  It is besides non a simpler merger of 60950-1 too 60065.
No appointment has been gear upward nevertheless for when “grandfathering” of the 60950-1 too 60065 standards ends.  It has been recommended past times but about exam regime that if a production is going to move removed from the marketplace past times 2018, too therefore create non function along alongside certifying to IEC 62368.  As in that location may move but about regions that cause got non accepted the novel standard, products that volition move on the marketplace afterward 2018 should expect at obtaining certification to IEC 62368, but maintain the existing 60950-1 too 60065 certifications.

Does this hateful that ability render manufacturers should outset transitioning over now?  No, the IEC commission recognizes this would impose a huge burden on everyone’s resources, including the certification bodies.  Clause 4.1.1 states that “Components too subassemblies that comply alongside IEC 60950-1 or IEC 60065 are acceptable equally purpose of equipment covered past times this criterion without farther evaluation other than to laissez passer on consideration to the appropriate utilisation of the component or sub-assembly inwards the destination product.”
One snippet of data I constitute this week; always wonder where the numbering convention of standards comes from?  If a criterion is IEC 50xxx it is based on a criterion of CENELEC (European Committee for Electrotechnical Standardization) origin.  If it is IEC 55xxx, it is based on CISPR (Special international commission on radio interference) origins.  For standards IEC 6xxxx, they originate from the IEC (International Electrotechnical Commission).
Power Guy

Friday, 14 December 2018

Info!! Portable Generators In Addition To Electronic Ability Supplies

Portable diesel fuel generator sets are ofttimes used to provide air-conditioning ability to temporary outdoor populace events, similar festivals, promotions in addition to concerts.  It is right away mutual to cause got large hard disk covert displays in addition to a host of other electronics existence used to provide additional multimedia.
When asked close running electronic ability supplies on portable generators, nosotros tend to catch the waveform quality, distortion in addition to high voltage dissonance spikes.  Upon farther research, this may non travel our greatest concern.

I elevate portable generators, rather than the fixed location, back-up generators that many facilities cause got inward house against ability outages.  The fixed generator would typically provide ability to a issue of dissimilar charge types, such equally heating, cooling, lighting, mechanism in addition to role equipment.  These loads would change, merely non significantly during operation, in addition to it would travel reasonably prophylactic to assume that at that spot would travel a “base-load” that remains introduce at all times.


With a portable location, that mightiness non travel the case, peculiarly during a interruption inward the consequence schedule or at the terminate of a laid when the ability depict drops dramatically.  When this occurs, at that spot could travel pregnant ascent inward the generator output voltage earlier it compensates for the lite load.


Generator Voltage alongside Sudden Load Change

Until ISO 8528 was published, generator specifications were governed past times local province standards, alongside many of the tests exclusively ensuring that the generator could direct maintain in addition to recover from large charge steps. Now, nether the governor department of the standard, inward department ISO 8528-1-7, the reply rule states 4 performance standards.

Class G1 – Used for applications where the connected loads exclusively require the basic parameters to travel specified.  This includes full general role applications similar lighting in addition to electrical loads which tin easily withstand the input voltage surges.

Class G2 – Required for applications where rule is non that critical in addition to temporary deviations are acceptable.  Lighting systems, pumps, fans in addition to hoists cause got some tolerance to frequency in addition to voltage.

Class G3 – Applications where the equipment demands are moderately severe in addition to includes telecommunication equipment in addition to thyristor-controlled loads.

Class G4 – Required for applications where the demands are extremely severe.  This typically includes data-processing in addition to reckoner equipment.

The limits for these deviations are shown below.





*Class G4 systems are commonly client specified

For dissimilar regions to a greater extent than or less the globe this agency the next overshoot profiles are possible:




The input voltage rating for many off the shelf AC-DC ability supplies is 85/90Vac to 264Vac.  Recently though, a issue of manufacturers cause got added a peak voltage rating of 300Vac for 5 seconds.  This is commonly constitute on enclosed type of product, similar TDK-Lambda’s RWS-B serial of l to 600W industrial ability supplies.



TDK-Lambda’s RWS-B

Looking at the tables above, the newer generation of ability supplies alongside a peak rating of 300Vac for 5 seconds may travel used on Class G3 generators.  Depending on the extent of the anticipated charge changes where at that spot is a base-line of fixed load, tin in all likelihood travel used alongside Class G2.

As opened upwardly frame (embedded) ability supplies tend to travel used inward ITE equipment, that surge rating is non commonly specified, in addition to a Class G4 generator should travel utilized.

The trouble organisation is that the selection of generator volition in all likelihood prevarication alongside the consequence organiser, in addition to they may opt for a lower toll Class G1 or G2 if they are non familiar alongside the standards.  If an equipment manufacturer believes that their production may teach used alongside portable generators, they should catch using an AC-DC ability render alongside a 300Vac surge rating.  Any production literature should province the minimum shape of generator to travel used for reliable operation.

Info!! Division Of Loose Energy Marking 6 Loose Energy Efficiency Standards For External Ability Supplies

I lately received a query from 1 of our sales people almost to what extent the novel Department of Energy’s Level VI volition touching on our customers, in addition to asked me to comment on it.  As park amongst my blogs, permit us aspect at the background.

The ability provide industry, inward special those who manufacture external or adapter ability supplies, has been aware of the US of America Department of Energy’s legislation on the efficiency standards for External Power Supplies (EPS).   This legislation was made terminal on Apr 11, 2014 in addition to comes into upshot Feb 10, 2016.  The intent is to cut back waste materials unloose energy both from off-load functioning in addition to normal operation.

Details of this lengthy, simply detailed, terminal ruling tin last constitute on this link: http://www.regulations.gov/#!documentDetail;D=EERE-2008-BT-STD-0005-0219

I hollo back many years dorsum when unloose energy efficiency standards for ability supplies were outset discussed.  Initially the reaction was “it is alone a few Watts, why bother”, simply amongst the staggering expose of external ability supplies instantly existence used (and it is expected to grow inward hereafter years) those few Watts presently adds upward to billions of dollars inward electricity in addition to the associated environmental pollution.

Most people locomote out their laptop/tablet/phone chargers plugged inward 24 hours a day, in addition to that applies to numerous gaming consoles in addition to other electronic equipment.  Power supplies locomote along to describe ability when non supplying charge in addition to legislation has been introduced to gear upward (decreasing) limits twelvemonth on twelvemonth past times multiple bodies.  In improver that legislation has gradually increased the minimum operating efficiency – this is measured at 4 loading levels; 25, 50, 75, in addition to 100 per centum of maximum rated output current.

There has been though, roughly scrap in addition to confusion almost what types of EPSs are genuinely covered past times the legislation.  This is pregnant every bit the DoE ruling forbids the imports of these types of ability supplies afterwards the Feb deadline if they produce non run into the novel efficiency standards.  It is made clear that EPSs for roughly medical applications (those requiring FDA approving in addition to listing) are exempt.  Spares are too excluded from the import ban.

Looking at the terminal ruling web-link provided above, it states inward department III General Discussion, B. Product Classes in addition to Scope of Coverage, 1. General:

An “external ability supply” is an external ability provide circuit that is used to convert household electrical electric current into DC electrical current or lower-voltage air-conditioning electrical current to operate a consumer product.

1. Is designed to convert business voltage air-conditioning input into lower voltage air-conditioning or DC output;
2. is able to convert to alone 1 air-conditioning or DC output voltage at a time;
3. is sold with, or intended to last used with, a dissever end-use production that constitutes the top dog load;
4. is contained inward a dissever physical enclosure from the end-use product;
5. is connected to the end-use production via a removable or hard-wired male/female electrical connection, cable, cord, or other wiring; and
6. has nameplate output ability that is less than or equal to 250 watts.

Section 2: definition of Consumer Product” is where the DoE noted that roughly companies accept made comments questioning the vagueness of the term.  Schneider Electric commented that the definition of consumer production is “virtually unbounded” in addition to “provides no definitive methods to distinguish commercial or industrial products from consumer products.”

The DoE ruling refers to an EPCA (Energy Policy in addition to Conservation) document that defines a consumer production as:

 “any article of a type that consumes or is designed to eat unloose energy in addition to which, to whatever pregnant extent, is distributed inward commerce for personal role or consumption past times individuals.”  For clarification, manufacturers are advised to consult this document: 

https://www1.eere.energy.gov/buildings/appliance_standards/pdfs/cce_faq.pdf

To answer our salesperson’s query - 1 affair is for sure, embedded (installed internally to the halt equipment) in addition to DIN rails ability supplies are non affected past times this legislation.  It alone applies to EPSs that are contained inward a dissever physical enclosure from the end-use product.

Does this touching on an EPS designed for in addition to sold for role amongst commercial or industrial products?  I think in that place volition all the same last roughly scrap on that, simply in that place is rigid evidence inward the terminal ruling that they are non covered in addition to thence exempt.  The document refers to “household electrical current”, “personal use” in addition to “consumption past times individuals”.  It is real clear that if an EPS manufacturer is producing a production that could probable halt upward inward your home, it has to abide amongst the legislation.

As a note, TDK-Lambda has launched a expose of external ability supplies that comply amongst Level VI efficiency standards.  TDK-Lambda’s novel industrial products too accept depression off-load ability draws in addition to efficiencies inward excess of 90%.

Power Guy



Info!! How Volition The Ability Furnish Manufacture Hold Upward Affected Yesteryear En 55032 Replacing En 55022?


In 2014 the Hazard-Based Safety Engineering (HBSE) measure IEC 62368-1 was announced combining the Information Technology Equipment (ITE) measure EN 60950-1 as well as the audio, video as well as like electronic apparatus security measure EN 60065.  This mensuration was taken every minute at that spot was no longer a clear Definition betwixt ITE as well as multimedia equipment alongside advent of cyberspace connected TVs, smartphones as well as other domicile amusement products.
Now the EMC standards are too beingness combined as well as every minute of March 5th, 2017, EN 55022, EN 55013 as well as EN 55103 volition last replaced yesteryear i unified emission requirements measure called EN 55032.  The electrical flow “Electromagnetic compatibility of multimedia equipment” was outset published inward May 2012 every minute EN 55032:2012+AC 2013, volition last withdrawn on May fifth 2018.  EN 55032:2015+AC:2016, which was announced May 2015 as well as published Feb 2016, has already superseded the 2012 standard.
The 3 standards that are beingness replaced yesteryear EN 55032 are:
EN 55022: Information Technology Equipment, Radio disturbance characteristics. Limits as well as methods of test.
EN 55013: Sound as well as Television Broadcast Receivers as well as Associated Equipment.
EN 55103: Audio, Video as well as Entertainment Lighting Equipment for Professional Use.
Fortunately for those inward the ability render manufacture serving the ITE marketplace position who guide maintain relied on EN 55022 every minute their heart as well as soul measure for many years, at that spot are no changes to the exam requirements.  The multimedia equipment (MME) makers volition guide maintain additional exam requirements to interface ports, port type as well as emissions from cabling.  The individuals that laid as well as sign their company’s CE Declaration of Conformity volition last kept busy updating their forms though!
Power Guy

Info!! An Update To The Transition From Iec 60950-1 To Iec 62368-1


On a weblog shipping service dorsum inward March 2015, I mentioned that a Hazard-Based Safety Engineering (HBSE) IEC 62368-1 measure volition live replacing IEC 60950-1 as well as IEC 60065, roofing hazards as well as gamble prevention for ITE (Information Technology Equipment) as well as well / visual equipment.

The transition appointment to EN 62368-1:2014 has at i time been extended eighteen months to Dec 20th, 2020 for novel submittals (or a pregnant change of the existing 60950/60065 file) inward the EU.  UL has too announced that the UL 62368-1 Edition No. 2 appointment is at i time Dec 20th, 2020. Influenza A virus subtype H5N1 issue of other countries accept adopted the standard, including Australia, Singapore, Malaysia, Nippon as well as Russia.  No exact appointment has been published for other countries similar China, Taiwan, Republic of Korea as well as Argentina.

The novel measure uses a Hazard Based Safety Engineering (HBSE) scientific discipline discipline, as well as operates inward 4 steps:

1.      Identifying energy sources inward the product

2.      Classifying the liberate energy for the potential of causing injury or harm

3.      Identify the necessary safeguards needed to protect from those energy sources

4.      Qualify the safeguards equally effective

The Energy Source ES classification handles the outcome on the trunk for a issue of hazards.  See Table 1 for lawsuit of the ii nearly relevant to ability supplies – electrical as well as thermal energy.

Energy Source class
Effect on the Body
Effect on combustible material
Class 1
Detectible, but non painful
Unlikely ignition
Class 2
Painful, but non an injury
Possible ignition, but limited
Class 3
An injury
Likely ignition, increment rapid & swift

Table 1 Energy Source classification

In addition, a iii someone scenario has been adopted for 62368-1 (see Table 2).            

Person
Description (See measure for total details)
Ordinary Person
A someone who is a user or is unopen yesteryear to the equipment
Instructed Person
A someone that is trained to position sources of hurting causing liberate energy as well as avoid them. Must non live exposed to injury causing liberate energy sources, fifty-fifty during a unmarried error condition
Skilled Person
A someone who has the preparation to recognize & avoid liberate energy sources that could crusade hurting or injury.  Must live protected against accidental contact alongside injury causing liberate energy sources

Table 2: Description of types of person


Depending on the Person type as well as the Energy Class, Safeguards accept to live inward house to protect that Person.  See Figure 1.



Figure 1: Protection for an Ordinary Person alongside dissimilar Energy Classes

As an example, i little alter ability render manufacturers may accept to brand to their designs to run into IEC 62369-1, concerns “capacitance discharge” of the air conditioning input. 

Figure 2 shows the typical schematic of an EMI filter department of a ability render as well as the location of a resistor that discharges the Line to Neutral X capacitors subsequently the air conditioning has been removed.  This avoids a user unplugging an air conditioning plug, touching the pins as well as getting an electrical shock.



Fig 2: EMI Filter Schematic

If the job cord was removed from the air conditioning plug at the peak of a 240V air conditioning cycle, as well as then the voltage would live 339Vdc.  The fourth dimension for that to decay to a rubber voltage depends upon the values of the X capacitor(s), the Line to Neutral resistor as well as whatsoever loading of the ability render converter circuitry.

IEC 60950-1 states that subsequently i bit that voltage has to live at a maximum of 42.4Vpk.  IEC 62368-1 states that for an X capacitance of 300nF or greater, subsequently ii seconds, the bound is 60Vpk inward normal status or 120Vpk inward a unmarried error condition.

A 10W ability telephone charger volition accept a rattling little X capacitance as well as a high value discharge resistor. Under 62368-1, if that resistor failed (a unmarried error condition) the ability render would belike nonetheless run into the 60Vpk status subsequently 2 seconds.  From Figure 1, this nonetheless complies alongside no Basic Safeguard is needed, fifty-fifty for an “Ordinary Person”.

A higher wattage ability render on the other hand, volition accept a much larger X capacitance.  With a unmarried error condition, the loss of the bleed resistor may resultant inward a voltage of greater than 120Vpk subsequently 2 seconds.  That would as well as then live an ES2 - Class 2 Energy Source - as well as from Figure 1, a Basic Safeguard would bespeak to live inward place.  Instead of only i bleed resistor, a bit i would bespeak to live added, inward parallel alongside the first.  The values of the resistor would live sized accordingly to ensure that the loss of one, would nonetheless discharge the X capacitor to a maximum of 120Vdc subsequently 2 seconds.

Supplementary Safeguards would live used inward other parts of the ability render circuit inward the same agency equally reinforced or double insulated is inward 60950-1.

One side outcome of the ES1 as well as ES2 limits is that IEC 62368-1 deems a 48V or fifty-fifty a 36V output ability render inward hiccup trend over electrical current equally an air conditioning output.  The ES1 limits for DC are 60V, but for upward to 1kHz that drops to 30Vrms or 42.2Vpk.  IEC 60950-1 recognizes that equally SELV, but nether the novel measure that would live ES2 as well as the output should non live made accessible to an Ordinary Person.  Pins as well as connectors non accessible yesteryear a blunt probe are exempt.

Power Guy